Browse
Subjects
Records with Subject: Process Control
451. LAPSE:2023.32481
Transformer Fault Diagnosis Model Based on Improved Gray Wolf Optimizer and Probabilistic Neural Network
April 20, 2023 (v1)
Subject: Process Control
Keywords: fault diagnosis, IEC three-ratio method, improved gray wolf optimizer, power transformer, probabilistic neural network
Dissolved gas analysis (DGA) based in insulating oil has become a more mature method in the field of transformer fault diagnosis. However, due to the complexity and diversity of fault types, the traditional modeling method based on oil sample analysis is struggling to meet the industrial demand for diagnostic accuracy. In order to solve this problem, this paper proposes a probabilistic neural network (PNN)-based fault diagnosis model for power transformers and optimizes the smoothing factor of the pattern layer of PNN by the improved gray wolf optimizer (IGWO) to improve the classification accuracy and robustness of PNN. The standard GWO easily falls into the local optimum because the update mechanism is too single. The update strategy proposed in this paper enhances the convergence ability and exploration ability of the algorithm, which greatly alleviates the dilemma that GWO is prone to fall into local optimum when dealing with complex data. In this paper, a reliability analysis of t... [more]
452. LAPSE:2023.32463
Zero-Width Quasi-Sliding Mode Band in the Presence of Non-Matched Uncertainties
April 20, 2023 (v1)
Subject: Process Control
Keywords: discrete-time systems, robust control, sliding mode control
Sliding mode control strategies are well known for ensuring robustness of the system with respect to disturbance and model uncertainties. For continuous-time plants, they achieve this property by confining the system state to a particular hyperplane in the state space. Contrary to this, discrete-time sliding mode control (DSMC) strategies only drive the system representative point to a certain vicinity of that hyperplane. In established literature on DSMC, the width of this vicinity has always been strictly greater than zero in the presence of uncertainties. Thus, ideal sliding motion was considered impossible for discrete-time systems. In this paper, a new approach to DSMC design is presented with the aim of driving the system representative point exactly onto the sliding hyperplane even in the presence of uncertainties. As a result, the quasi-sliding mode band width is effectively reduced to zero and ideal discrete-time sliding motion is ensured. This is achieved with the proper sele... [more]
453. LAPSE:2023.32451
Design of a Damping Controller Using the SCA Optimization Technique for the Improvement of Small Signal Stability of a Single Machine Connected to an Infinite Bus System
April 20, 2023 (v1)
Subject: Process Control
Keywords: eigenvalues, objective function, power system stability, power system stabilizer parameters, sine cosine algorithm, single machine infinite bus
This paper discusses the use of a stochastic metaheuristic population-based optimization algorithm known as the sine cosine algorithm (SCA) to design the parameters of a power system stabilizer (PSS) for damping electromechanical oscillations in a single machine connected to a large power system. The design of the PSS parameters was formulated as an optimization problem to minimize the objective function value. The SCA was used to obtain the best values of the PSS parameters under the objective function. Simulation was carried out by a linearized power system model. The lead lag controller was used as the PSS structure and the results from that were compared with those obtained by moth flame optimization and evolutionary programming. The results showed that the SCA is more effective than are the other techniques in exploration and exploitation to tune the PSS parameters and enhance the power system stability by damping oscillations in a range of loading conditions.
454. LAPSE:2023.32420
Accuracy Improvement of Transformer Faults Diagnostic Based on DGA Data Using SVM-BA Classifier
April 20, 2023 (v1)
Subject: Process Control
Keywords: DGA, DGALab, SVM-BA classifier, transformer faults
The main objective of the current work was to enhance the transformer fault diagnostic accuracy based on dissolved gas analysis (DGA) data with a proposed coupled system of support vector machine (SVM)-bat algorithm (BA) and Gaussian classifiers. Six electrical and thermal fault classes were categorized based on the IEC and IEEE standard rules. The concentration of five main combustible gases (hydrogen, methane, ethane, ethylene, and acetylene) was utilized as an input vector of the two classifiers. Two types of input vectors have been tested; the first input type considered the five gases in ppm, and the second input type considered the gases introduced in the percentage of the sum of the five gases. An extensive database of 481 had been used for training and testing phases (321 data samples for training and 160 data samples for testing). The SVM model conditioning parameter “λ” and penalty margin parameter “C” were adjusted through the bat algorithm to develop a maximum accuracy rate... [more]
455. LAPSE:2023.32381
Common-Mode Voltage Harmonic Reduction in Variable Speed Drives Applying a Variable-Angle Carrier Phase-Displacement PWM Method
April 20, 2023 (v1)
Subject: Process Control
Keywords: harmonic distortion, metaheuristic search algorithms, power converters, pulse-width modulation
Electric variable speed drives (VSD) have been replacing mechanic and hydraulic systems in many sectors of industry and transportation because of their better performance and reduced cost. However, the electric systems still face the issue of being considered less reliable than the mechanical ones. For this reason, researchers have been actively investigating effective ways to increase the reliability of such systems. This paper is focused on the analysis of the common-mode voltage (CMV) generated by the operation of the VSDs which directly affects to the lifetime and reliability of the complete system. The method is based on the mathematical description of the harmonic spectrum of the CMV depending on the PWM method implementation. A generalized PWM method where the carriers present a variable phase-displacement is developed. As a result of the presented analysis, the CMV reduction is achieved by applying the PWM method with optimal carrier phase-displacement angles without any extern... [more]
456. LAPSE:2023.32374
Methods of Stability Control of Perovskite Solar Cells for High Efficiency
April 20, 2023 (v1)
Subject: Process Control
Keywords: electron-transporting layer, hole transport layer, perovskite solar cell, solvent additives, structure modification, thin film
The increasing demand for renewable energy devices over the past decade has motivated researchers to develop new and improve the existing fabrication techniques. One of the promising candidates for renewable energy technology is metal halide perovskite, owning to its high power conversion efficiency and low processing cost. This work analyzes the relationship between the structure of metal halide perovskites and their properties along with the effect of alloying and other factors on device stability, as well as causes and mechanisms of material degradation. The present work discusses the existing approaches for enhancing the stability of PSC devices through modifying functional layers. The advantages and disadvantages of different methods in boosting device efficiency and reducing fabrication cost are highlighted. In addition, the paper presents recommendations for the enhancement of interfaces in PSC structures.
457. LAPSE:2023.32372
Shipboard Power Management for Failure Mode Using the Hybrid MPC Approach
April 20, 2023 (v1)
Subject: Process Control
Keywords: failure mode, hybrid model predictive control, real-time optimization, reconfiguration, shipboard power system
Shipboard integrated power systems, the key technology of ship electrification, call for effective failure mode power management control strategy to achieve the safe and reliable operation in dynamic reconfiguration. Considering switch reconfiguration with system dynamics and power balance restoration after reconfiguration, in this paper, the optimization objective function of optimal management for ship failure mode is established as a hybrid model predictive control problem from the perspective of hybrid system. To meet the needs for fast computation, a hierarchical hybrid model predictive control algorithm is proposed, which divides the original optimization problem into two stages, and reduces the computation complexity by relaxing constraints and the minimum principle. By applying to a real-time simulator in two scenarios, the results verify the effectivity of the proposed method.
458. LAPSE:2023.32366
Optimal Control Strategies for Switchable Transparent Insulation Systems Applied to Smart Windows for US Residential Buildings
April 20, 2023 (v1)
Subject: Process Control
Keywords: Energy Efficiency, genetic algorithms, optimal controls, peak demand, residential buildings, switchable insulation systems, variable SHGC, variable U-value, windows
This paper evaluates the potential energy use and peak demand savings associated with optimal controls of switchable transparent insulation systems (STIS) applied to smart windows for US residential buildings. The optimal controls are developed based on Genetic Algorithm (GA) to identify the automatic settings of the dynamic shades. First, switchable insulation systems and their operation mechanisms are briefly described when combined with smart windows. Then, the GA-based optimization approach is outlined to operate switchable insulation systems applied to windows for a prototypical US residential building. The optimized controls are implemented to reduce heating and cooling energy end-uses for a house located four US locations, during three representative days of swing, summer, and winter seasons. The performance of optimal controller is compared to that obtained using simplified rule-based control sets to operate the dynamic insulation systems. The analysis results indicate that opt... [more]
459. LAPSE:2023.32354
A Hybrid MPPT Controller Based on the Genetic Algorithm and Ant Colony Optimization for Photovoltaic Systems under Partially Shaded Conditions
April 20, 2023 (v1)
Subject: Process Control
Keywords: ant colony optimization (ACO), genetic algorithm (GA), maximum power point tracking (MPPT), partial shade, photovoltaic systems
A maximum power point tracking (MPPT) controller was used to make the photovoltaic (PV) module operate at its maximum power point (MPP) under changing temperature and sunlight irradiance. Under partially shaded conditions, the characteristic power−voltage (P−V) curve of the PV modules will have more than one maximum power point, at least one local maximum power point and a global maximum power point. Conventional MPPT controllers may control the PV module array at the local maximum power point rather than the global maximum power point. MPPT control can be also implemented by using soft computing methods (SCM), which can handle the partial shade problem. However, to improve the robustness and speed of the MPPT controller, a hybrid MPPT controller has been proposed that combines two SCMs, the Genetic Algorithm (GA) and Ant Colony Optimization (ACO). Matlab was used in a simulation of a GA-ACO MPPT controller where four SunPower SPR-305NE-WHT-D PV modules with a maximum power of 305.226... [more]
460. LAPSE:2023.32340
Sliding Mode Control with Minimization of the Regulation Time in the Presence of Control Signal and Velocity Constraints
April 20, 2023 (v1)
Subject: Process Control
Keywords: finite time convergence, reaching phase elimination, robust control, settling time minimization, sliding mode control, time-varying sliding line
In this paper, the design of the terminal continuous-time sliding mode controller is presented. The influence of the external disturbances is considered. The robustness for the whole regulation process is obtained by adapting the time-varying sliding line. The representative point converges to the demand state in finite time due to the selected shape of the nonlinear switching curve. Absolute values of control signal, system velocity and both of these quantities are bounded from above and considered as system constraints. In order to evaluate the dynamical performance of the system, the settling time is selected as a quality index and it is minimized. The approach presented in this paper is particularly suited for systems in which one state (or a set of states) is the derivative of the other state (or a set of states). This makes it applicable to a wide range of electromechanical systems, in which the states are the position and velocity of the mechanical parts.
461. LAPSE:2023.32333
Boundary Conditions for Transient and Robust Performance of a Reduced-Order Model-Based State Feedback Controller with PI Observer
April 20, 2023 (v1)
Subject: Process Control
Keywords: dc motor, proportional-integral observer, reduced-order model-based controller, robust control, Routh-Hurwitz criterion, stability analysis
One common technique employed in control system design to minimize system model complexity is model order reduction. However, controllers designed by using a reduced-order model have the potential to cause the closed-loop system to become unstable when applied to the original full-order system. Additionally, system performance improvement techniques such as disturbance observers produce unpredictable outcomes when augmented with reduced-order model-based controllers. In particular, the closed-loop system stability is compromised when a large value of observer gain is employed. In this paper, a boundary condition for the controller and observer design parameters in which the closed-loop system stability is maintained is proposed for a reduced-order proportional-integral observer compensated reduced-order model-based controller. The boundary condition was obtained by performing the stability analysis of the closed-loop system using the root locus method and the Routh-Hurwitz criterion. B... [more]
462. LAPSE:2023.32308
PV Modules Interfacing Isolated Triple Active Bridge for Nanogrid Applications
April 20, 2023 (v1)
Subject: Process Control
Keywords: control analysis, DC nanogrid, PV module, three port converter, triple active bridge
DC nanogrid architectures with Photovoltaic (PV) modules are expected to grow significantly in the next decades. Therefore, the integration of multi-port power converters and high-frequency isolation links are of increasing interest. The Triple Active Bridge (TAB) topology shows interesting advantages in terms of isolation, Zero Voltage Switching (ZVS) over wide load and input voltage ranges and high frequency operation capability. Thus, controlling PV modules is not an easy task due to the complexity and control stability of the system. In fact, the TAB power transfer function has many degrees of freedom, and the relationship between any of two ports is always dependent on the third one. In this paper we analyze the interfacing of photovoltaic arrays to the TAB with different solar conditions. A simple but effective control solution is proposed, which can be implemented through general purpose microcontrollers. The TAB is applied to an islanded DC nanogrid, which can be useful and rea... [more]
463. LAPSE:2023.32297
Impedance Reshaping Control Strategy for Improving Resonance Suppression Performance of a Series-Compensated Grid-Connected System
April 20, 2023 (v1)
Subject: Process Control
Keywords: impedance reshaping, inverter, resonance suppression, series compensation
In the series-compensated grid-connected system (SCGCS), there is an impedance interaction between the inverter impedance and the grid impedance that is prone to cause resonance in the SCGCS. In this paper, firstly, considering the effects of the phase-locked loop (PLL), current-loop, and frequency coupling, the broadband impedance model of the SCGCS is established. The stability of the SCGCS is analyzed by the impedance-based Nyquist stability criterion. It is found from the stability analysis that the impedance interaction between the inverter impedance and the grid impedance is the leading cause of the resonance. An impedance reshaping based resonance suppression method is proposed to suppress the resonance. The phase characteristics of the inverter equivalent output impedance are reshaped from the perspective of impedance. The phase margin at the intersection frequency of the inverter impedance and the grid impedance is improved. The proposed resonance suppression approach mainly c... [more]
464. LAPSE:2023.32245
WAMS-Supported Power Mismatch Optimization for Secure Intentional Islanding
April 20, 2023 (v1)
Subject: Process Control
Keywords: intentional controlled islanding, Optimization, under-frequency load shedding, WAMS
It is expected that a coordinated operation of several system integrity protection schemes will become a necessity in the future. This research represents an innovative strategy for coordinating under-frequency load shedding and intentional controlled islanding schemes for improving electric power system stability and resilience. In the great majority of real-world cases, both approaches follow conventional tactics, i.e., disconnecting a fixed number of feeders at predefined frequency thresholds and isolating a predefined area of a power system regardless of the actual conditions. Under the newly arisen network conditions in which weather-dependent distributed energy sources introduce a significant level of intermittency, conventional approaches need to be upgraded in order to retain a high level of power system operation security. In this paper, a mixed-integer linear programming approach is used to adjust the island size, including/excluding additional substations according to the av... [more]
465. LAPSE:2023.32232
Numerical Modelling and Digitalization Analysis for a Photovoltaic Pumping System Placed in the South of Romania
April 20, 2023 (v1)
Subject: Process Control
Keywords: artificial intelligence (AI), control, digital platform, maximum power point tracking (MPPT), meteorological parameters, monitoring, performances, photovoltaic pumping system, simulation tools
The authors studied a working off-grid type photovoltaic (PV) pumping system for irrigation use. The methodology was based on digitalization analysis and numerical modeling as a preliminary stage. A mathematical model of the PV pumping installation considered the determination of the characteristic equations for all its components. These have been used together with the SISIFO simulation software to achieve the performances of the mechanical and electrical components of an advanced PV pumping system. Its global performance features, namely the monthly energy yield, monthly pumping yield, and monthly total performances (energy and flow rate) were introduced. Digital platform (DP) for PV systems characterized by three advanced technologies—machine learning (ML), digital twin (DT) and artificial intelligence (AI) was developed. The simulation results were discussed for a specific case study conducted for a location in the Southern Romania regarding the irrigation potential, taking into ac... [more]
466. LAPSE:2023.32224
Stator Fixed Deadbeat Predictive Torque and Flux Control of a PMSM Drive with Modulated Duty Cycle
April 20, 2023 (v1)
Subject: Process Control
Keywords: deadbeat predictive control, flux control, PMSM, torque control
Conventional deadbeat control strategies for permanent magnet synchronous machines (PMSMs) are commonly developed reference frames, however, coupling dynamics affect the performance drive, and rotational transformations are required for the synthesis of the final voltage vector (VV). To improve robustness against parameter variations and to directly synthesize the reference voltage vector, in this paper a deadbeat predictive torque and flux control for a PMSM is presented. The proposed controller is developed in the stationary reference frame (α−β). First, the reference VV is obtained from a predictive deadbeat controller. Then, the reference VV is applied to the power inverter by the combination of two voltage vectors. A duty cycle optimization is employed to calculate the required time for the application of each voltage vector. Experimental results based on an FPGA and a comparison of the conventional and the proposed deadbeat controller are presented to validate the proposed method... [more]
467. LAPSE:2023.32187
Enhancement of Advanced Metering Infrastructure Performance Using Unsupervised K-Means Clustering Algorithm
April 19, 2023 (v1)
Subject: Process Control
Keywords: advanced metering infrastructure (AMI), data aggregation points (DAPs), neighborhood area network (NAN), poisson point process (PPP), smart meters (SMs), unsupervised K-means clustering
Data aggregation may be considered as the technique through which streams of data gathered from Smart Meters (SMs) can be processed and transmitted to a Utility Control Center (UCC) in a reliable and cost-efficient manner without compromising the Quality of Service (QoS) requirements. In a typical Smart Grid (SG) paradigm, the UCC is usually located far away from the consumers (SMs), which has led to a degradation in network performance. Although the data aggregation technique has been recognized as a favorable solution to optimize the network performance of the SG, the underlying issue to date is to determine the optimal locations for the Data Aggregation Points (DAPs), where network coverage and full connectivity for all SMs deployed within the network are achieved. In addition, the main concern of the aggregation technique is to minimize transmission and computational costs. In this sense, the number of DAPs deployed should be as minimal as possible while satisfying the QoS requirem... [more]
468. LAPSE:2023.32185
A Digital Delay Compensation Method to Improve the Stability of LCL Grid-Connected Inverters
April 19, 2023 (v1)
Subject: Process Control
Keywords: active damping, delay compensation, digital delay, LCL-type grid-connected inverter
Grid-connected inverters are an important part of the connection between distributed power generation units and the large grid, and their stability is the basis for ensuring the safe operation of distributed power generation units. This study found that there is an inherent digital control delay in the three-phase LCL grid-connected inverter system. This characteristic causes the effective range of capacitive current feedback active damping to be reduced, the selection range of the active damping coefficient to be limited, and the phase at the open-loop cutoff frequency to be reduced. In order to reduce the impact of digital delay, this article conducts a detailed analysis of the characteristics of the first-order lead link that can be used as delay compensation, pointing out that its infinite gain when it obtains the optimal compensation effect will bring noise to the inverter system. This paper proposes a method of cascading digital filters for the first-order leading link to suppres... [more]
469. LAPSE:2023.32142
Review of Impedance-Based Analysis Methods Applied to Grid-Forming Inverters in Inverter-Dominated Grids
April 19, 2023 (v1)
Subject: Process Control
Keywords: control design, grid-forming, impedance, inverter, stability
As the use of distributed generation with power electronics-based interfaces increases, the separation between DC and AC parts of the grid is reduced. In such inverter-dominated AC grids, impedance-based analysis methods are proving to be more powerful than traditional state-space-based analysis methods. Even the conventional parameters and standards used to estimate the stability of generators and stronger grids cannot fully capture the dynamics of weaker, inverter-dominated grids. It then stands to reason that system impedances that are commonly used to analyze DC systems will be useful in the analysis of grid-forming inverters in these hybrid systems. To understand the value of studying the impedances of inverters and other elements in weak AC grids, this article reviews and describes the various ways in which impedance-based analyses can be used to define, assess, and improve the performance of grid-forming inverter controllers. An exemplary case using the conventional P-f/Q-V droo... [more]
470. LAPSE:2023.32119
Analysis of Daily Load Patterns Taking into Consideration PEVs Charging Stations in Seoul, South Korea
April 19, 2023 (v1)
Subject: Process Control
Keywords: charging station, controlled PEVs, daily load patterns, time of use (TOU), uncontrolled PEVs
This paper presents a methodology to calculate daily charging load curves in Seoul, South Korea, by taking into account plug-in electric vehicles (PEVs) charging stations, allowing Seoul’s government to determine the PEVs charging effect on the load. In particular, the study calculates the charging power of uncontrolled PEVs charging in terms of the daily operating characteristics of a vehicle traveling between home and workplace, with respect to PEVs charging stations in the city, according to the PEVs’ market share. For the controlled PEVs charging strategy based on morning and afternoon work-to-home and vice versa traffic characteristics and time-of-use (TOU) prices in Seoul, the study calculates daily load patterns of uncontrolled and controlled charging scenarios. After adding the calculated values to the existing load, the study assesses and compares their effects on the power grid. The results are as follows. If by 2030 the share of electric vehicles is 10%, compared to the exis... [more]
471. LAPSE:2023.32102
Novel Single-Phase Grid-Tied NPC Five-Level Converter with an Inherent DC-Link Voltage Balancing Strategy for Power Quality Improvement
April 19, 2023 (v1)
Subject: Process Control
Keywords: capacitor voltage balancing, grid-tied, NPC topology, power quality, single-phase multilevel converter, vector control
This paper presents a novel single-phase grid-tied neutral-point-clamped (NPC) five-level converter (SPFLC). Unlike the literature on five-level NPC topologies, the proposed one is capable of inherently balancing the voltage of the DC-link split capacitors. For this purpose, a simple Multicarrier Phase Disposition (MPD) Pulse Width Modulation (PWM) technique is used, thus avoiding both complex modifications to the Space Vector Modulation (SVM) and offset voltage injections into the carrier based (CB) PWM, as commonly done in most conventional balancing algorithms. Bearing in mind that the proposed balancing strategy only requires measuring the capacitors’ voltages and the sign of the converter output current, it has a very low complexity. The developed strategy is not only straightforwardly implemented but is also very effective for obtaining symmetrical and undistorted voltage levels from the proposed multilevel converter, as well as for significantly improving the power quality of th... [more]
472. LAPSE:2023.32089
Algorithm for Selecting Best Available Techniques in Polish Coking Plants Supporting Multi-Criteria Investment Decisions in European Environmental Conditions
April 19, 2023 (v1)
Subject: Process Control
Keywords: best available techniques, coking plants, investment decision support systems, reduction of air pollution
The tightened approach of the European Commission to the issue of meeting the levels of pollutant emissions to the environment, inextricably connected with the level of technology used, is a serious financial challenge for many European coke producers, therefore the main aim of the article is to develop an algorithm of conduct that allows a selection of the best available emission abatement techniques from the coking plant in conditions with multiple emission sources, taking into account technological, environmental, and economic criteria. This algorithm can be used as a universal tool supporting production managers in planning investments limiting the environmental impact of the coking plant in the most economically advantageous way, while using BAT techniques. In the development of the algorithm, a multi-criteria analysis and a scenario method were used, as well as a number of typical methods for measuring and reducing the level of emissions in the coke production process. Its demons... [more]
473. LAPSE:2023.32028
The Cost of Photovoltaic Forecasting Errors in Microgrid Control with Peak Pricing
April 19, 2023 (v1)
Subject: Process Control
Keywords: energy management, Model Predictive Control, PARODIS
Model predictive control (MPC) is widely used for microgrids or unit commitment due to its ability to respect the forecasts of loads and generation of renewable energies. However, while there are lots of approaches to accounting for uncertainties in these forecasts, their impact is rarely analyzed systematically. Here, we use a simplified linear state space model of a commercial building including a photovoltaic (PV) plant and real-world data from a 30 day period in 2020. PV predictions are derived from weather forecasts and industry peak pricing is assumed. The effect of prediction accuracy on the resulting cost is evaluated by multiple simulations with different prediction errors and initial conditions. Analysis shows a mainly linear correlation, while the exact shape depends on the treatment of predictions at the current time step. Furthermore, despite a time horizon of 24h, only the prediction accuracy of the first 75min was relevant for the presented setting.
474. LAPSE:2023.32022
Self-Tuning Observer for Sensor Fault-Tolerant Control of Induction Motor Drive
April 19, 2023 (v1)
Subject: Process Control
Keywords: current and speed estimation, fault-tolerant control, induction motor drive, model reference adaptive system, vector control
This paper introduces a new solution for the speed and current sensor fault-tolerant direct field-oriented control of induction motor drives. Two self-adjusting observers derived from a modified current-based model reference adaptive system (CB-MRAS) are presented. Finally, the recursive least squares method was used to estimate the parameters of the used observers. The method, in the proposed solution, provides a very fast and accurate finding of the observer parameters while maintaining relative simplicity and ease of implementation. The presented algorithm eliminates the CB-MRAS observer dependence on the induction motor parameters and also compensates for the inaccuracies in the evaluation of the stator voltage vector. The proposed fault-tolerant control offers the drive operation while either a speed sensor or one/two current sensors fault occurs. The drive still works with the direct field-oriented control even when no current sensors are healthy. The proposed scheme was simulate... [more]
475. LAPSE:2023.32021
Decentralized Voltage Control in Active Distribution Systems: Features and Open Issues
April 19, 2023 (v1)
Subject: Process Control
Keywords: active distribution systems, decentralized control, distributed energy resources, hierarchical decomposition, voltage control
Voltage control is becoming a key issue in active distribution systems, which are electric distribution networks characterized by a large penetration of DERs. Traditional voltage control devices, as well as the active and reactive powers injected by DERs, can be used as ancillary services to support voltage profiles along the distribution feeders. Due to the peculiar characteristics of active distribution systems, the decentralized control approach presents the most promising technical and economical features. In the paper, the decentralized voltage control structure is hierarchically decomposed into different control levels, characterized by different objectives and time frames. The primary and secondary control levels have been analyzed, always according to a decentralized approach. For each level, the various techniques for solving the voltage control problem that have been proposed in the literature are presented, and their main features compared. The main open issues related to th... [more]
[Show All Subjects]
[0.05 s]

