LAPSE:2023.2530v1
Published Article

LAPSE:2023.2530v1
Hydraulic Optimization of Closed Transformation of Open Sump for the Water Treatment Pumping Station
February 21, 2023
Abstract
Taking the closed modification of an open sump of a water treatment pump station as the research background, the hydraulic design criteria for the closed modification of the sump are put forward by combining numerical simulation, model test. Based on CFD technology, a water pumping station including closed sump, bellmouth, impeller, guide vane, elbow and outlet sump is simulated, and the hydraulic performance of the schemes under different parameters is analyzed and compared. The top floor clearance, width, back wall distance, and floor clearance of the sump are optimized hydraulically, and the hydraulic design criteria of the closed sump are obtained. The results show that when the recommended optimization parameters of the closed sump in this study are that the top floor height HD is 0.9 DL, the width B is 3.0 DL, the back wall distance T is from 0.4 DL, and the floor clearance C is 0.75 DL, the internal flow pattern and hydraulic of the closed sump is better. (DL is the diameter of bellmouth of water pumping station). The model test was set up to compare the hydraulic performance of the pumping station between CFD and the test. The results showed that the CFD data is in good agreement with the experimental data.
Taking the closed modification of an open sump of a water treatment pump station as the research background, the hydraulic design criteria for the closed modification of the sump are put forward by combining numerical simulation, model test. Based on CFD technology, a water pumping station including closed sump, bellmouth, impeller, guide vane, elbow and outlet sump is simulated, and the hydraulic performance of the schemes under different parameters is analyzed and compared. The top floor clearance, width, back wall distance, and floor clearance of the sump are optimized hydraulically, and the hydraulic design criteria of the closed sump are obtained. The results show that when the recommended optimization parameters of the closed sump in this study are that the top floor height HD is 0.9 DL, the width B is 3.0 DL, the back wall distance T is from 0.4 DL, and the floor clearance C is 0.75 DL, the internal flow pattern and hydraulic of the closed sump is better. (DL is the diameter of bellmouth of water pumping station). The model test was set up to compare the hydraulic performance of the pumping station between CFD and the test. The results showed that the CFD data is in good agreement with the experimental data.
Record ID
Keywords
closed sump, Computational Fluid Dynamics, geometrical parameter, hydraulic performance, Optimization
Subject
Suggested Citation
Cheng X, Chen X. Hydraulic Optimization of Closed Transformation of Open Sump for the Water Treatment Pumping Station. (2023). LAPSE:2023.2530v1
Author Affiliations
Cheng X: College of Water Resources & Civil Engineering, China Agricultural University, Beijing 100091, China
Chen X: College of Water Resources & Civil Engineering, China Agricultural University, Beijing 100091, China [ORCID]
Chen X: College of Water Resources & Civil Engineering, China Agricultural University, Beijing 100091, China [ORCID]
Journal Name
Processes
Volume
10
Issue
4
First Page
644
Year
2022
Publication Date
2022-03-25
ISSN
2227-9717
Version Comments
Original Submission
Other Meta
PII: pr10040644, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.2530v1
This Record
External Link

https://doi.org/10.3390/pr10040644
Publisher Version
Download
Meta
Record Statistics
Record Views
521
Version History
[v1] (Original Submission)
Feb 21, 2023
Verified by curator on
Feb 21, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.2530v1
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.08 seconds)
[0.08 s]