LAPSE:2023.20934
Published Article

LAPSE:2023.20934
Performance Simulation and Benefit Analysis of Ammonia Absorption Cooling and Heating Dual-Supply System Based on Off-Peak Electricity Heat Storage
March 21, 2023
Abstract
The energy consumption of urban central heating in northern China is two to four times that in northern Europe and other countries. Beijing has adopted measures, such as ‘coal to gas’ and ‘coal to electricity’, to reduce environmental pollution caused by central heating. Given a peak-to-valley difference in the electricity supply of power plant, which is uneven day and night, this study proposes to store the night-time off-peak electricity in the form of heat energy and drive the ammonia absorption system in the form of steam or hot water during peak or flat electricity. Simulation results of ammonia absorption cooling and heating dual-supply system show that heat source temperature increases, evaporation temperature increases, and cooling water temperature decreases are all beneficial to improve the refrigeration coefficient in the summer cooling condition. In the meantime, heat source temperature increases, evaporation temperature increases, and cooling water temperature decreases are beneficial for increasing the heating coefficient in the winter heating condition. The heating and cooling coefficients of the system are 1.38 and 0.65 in the optimal working condition in winter and summer. Benefit analysis shows that, compared with central heating and cold storage air conditioning, the system can save 576,000 tons of standard coal and 1.417 million tons of carbon dioxide if used in 12% of the cooling and heat supply areas in Beijing. The potential for energy saving and emission reduction is large.
The energy consumption of urban central heating in northern China is two to four times that in northern Europe and other countries. Beijing has adopted measures, such as ‘coal to gas’ and ‘coal to electricity’, to reduce environmental pollution caused by central heating. Given a peak-to-valley difference in the electricity supply of power plant, which is uneven day and night, this study proposes to store the night-time off-peak electricity in the form of heat energy and drive the ammonia absorption system in the form of steam or hot water during peak or flat electricity. Simulation results of ammonia absorption cooling and heating dual-supply system show that heat source temperature increases, evaporation temperature increases, and cooling water temperature decreases are all beneficial to improve the refrigeration coefficient in the summer cooling condition. In the meantime, heat source temperature increases, evaporation temperature increases, and cooling water temperature decreases are beneficial for increasing the heating coefficient in the winter heating condition. The heating and cooling coefficients of the system are 1.38 and 0.65 in the optimal working condition in winter and summer. Benefit analysis shows that, compared with central heating and cold storage air conditioning, the system can save 576,000 tons of standard coal and 1.417 million tons of carbon dioxide if used in 12% of the cooling and heat supply areas in Beijing. The potential for energy saving and emission reduction is large.
Record ID
Keywords
energy conservation, Energy Storage, off-peak electricity, performance simulation
Subject
Suggested Citation
Yin S, Shi Y, Tong L, Wang L, Ding Y. Performance Simulation and Benefit Analysis of Ammonia Absorption Cooling and Heating Dual-Supply System Based on Off-Peak Electricity Heat Storage. (2023). LAPSE:2023.20934
Author Affiliations
Yin S: School of Energy and Environmental Engineering, University of Science and Technology Beijing, Beijing 100083, China; Beijing Key Laboratory of Energy Saving and Emission Reduction in Metallurgical Industry, University of Science and Technology Beijing, Be
Shi Y: School of Energy and Environmental Engineering, University of Science and Technology Beijing, Beijing 100083, China
Tong L: School of Energy and Environmental Engineering, University of Science and Technology Beijing, Beijing 100083, China; Beijing Key Laboratory of Energy Saving and Emission Reduction in Metallurgical Industry, University of Science and Technology Beijing, Be
Wang L: School of Energy and Environmental Engineering, University of Science and Technology Beijing, Beijing 100083, China; Beijing Key Laboratory of Energy Saving and Emission Reduction in Metallurgical Industry, University of Science and Technology Beijing, Be
Ding Y: College of Chemical Engineering, University of Birmingham, Birmingham B15 2TT, UK
[Login] to see author email addresses.
Shi Y: School of Energy and Environmental Engineering, University of Science and Technology Beijing, Beijing 100083, China
Tong L: School of Energy and Environmental Engineering, University of Science and Technology Beijing, Beijing 100083, China; Beijing Key Laboratory of Energy Saving and Emission Reduction in Metallurgical Industry, University of Science and Technology Beijing, Be
Wang L: School of Energy and Environmental Engineering, University of Science and Technology Beijing, Beijing 100083, China; Beijing Key Laboratory of Energy Saving and Emission Reduction in Metallurgical Industry, University of Science and Technology Beijing, Be
Ding Y: College of Chemical Engineering, University of Birmingham, Birmingham B15 2TT, UK
[Login] to see author email addresses.
Journal Name
Energies
Volume
12
Issue
12
Article Number
E2298
Year
2019
Publication Date
2019-06-16
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en12122298, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.20934
This Record
External Link

https://doi.org/10.3390/en12122298
Publisher Version
Download
Meta
Record Statistics
Record Views
520
Version History
[v1] (Original Submission)
Mar 21, 2023
Verified by curator on
Mar 21, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
http://psecommunity.org/LAPSE:2023.20934
Record Owner
Auto Uploader for LAPSE
Links to Related Works
