Huge efforts have been made in recent decades to improve energy saving in the building sector, particularly focused on the role of façades. Among the explored viable solutions, climate-adaptive building shells [CABS] consider promising solutions to control solar radiation, both in terms of illuminance and heating levels, but are still piloting these solutions due to their complex designs and necessary costs. The present study aims to provide a speedy but reliable methodology to evaluate the potential impacts of adopting active/passive CABS systems during the preliminary design stage. The proposed methodology allows the evaluation and comparison, when multiple options are considered, of the effects of each solution in terms of the energy needs, thermal comfort and lighting, while reducing the required effort and time for an extensive analysis of the overall building level. This is based on the use of a “virtual test room” where different conditions and configurations can be explored. A case study in the city of Bologna is included for demonstration purposes. The achieved results support the decisions made regarding energy behavior (over/under heating), indoor comfort, lighting and energy at an early design stage.
Huge efforts have been made in recent decades to improve energy saving in the building sector, particularly focused on the role of façades. Among the explored viable solutions, climate-adaptive building shells [CABS] consider promising solutions to control solar radiation, both in terms of illuminance and heating levels, but are still piloting these solutions due to their complex designs and necessary costs. The present study aims to provide a speedy but reliable methodology to evaluate the potential impacts of adopting active/passive CABS systems during the preliminary design stage. The proposed methodology allows the evaluation and comparison, when multiple options are considered, of the effects of each solution in terms of the energy needs, thermal comfort and lighting, while reducing the required effort and time for an extensive analysis of the overall building level. This is based on the use of a “virtual test room” where different conditions and configurations can be explored. A case study in the city of Bologna is included for demonstration purposes. The achieved results support the decisions made regarding energy behavior (over/under heating), indoor comfort, lighting and energy at an early design stage.
Record ID
Keywords
climate change, climate-adaptive building shells, Energy Efficiency, shape-memory alloy, sustainable design
Subject
Suggested Citation
Fabbri K, Gaspari J. A Replicable Methodology to Evaluate Passive Façade Performance with SMA during the Architectural Design Process: A Case Study Application. (2023). LAPSE:2023.19035
Author Affiliations
Journal Name
Energies
Volume
14
Issue
19
First Page
6231
Year
2021
Publication Date
2021-09-30
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14196231, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.19035
This Record
External Link

https://doi.org/10.3390/en14196231
Publisher Version
Download
Meta
Record Statistics
Record Views
248
Version History
[v1] (Original Submission)
Mar 9, 2023
Verified by curator on
Mar 9, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
http://psecommunity.org/LAPSE:2023.19035
Record Owner
Auto Uploader for LAPSE
Links to Related Works