LAPSE:2023.18948
Published Article

LAPSE:2023.18948
Dual Active Bridge as a DC Link Current Pulsation Compensator in Energy Storage Applications
March 9, 2023
Abstract
This paper presents a system for compensating DC link current pulsation in four-wire inverters with energy storage operating under unbalanced load conditions. This phenomenon occurs when an inverter with an independent power control in each of the phases attempts to locally balance the voltage imbalance in the grid. Such a condition creates a DC link current pulsation, which is destructive for energy storage connected to the DC link. The conditions when this situation appears are presented in detail in the paper. A solution to this problem is proposed in the form of a dual active bridge converter and a capacitor bank to actively compensate this pulsation. The control algorithm is proposed based on a proportional-resonant controller. This paper presents the technical background and method by which the controller parameters were calculated, implemented and tested in a real-time system. The test results are presented and discussed, concluding that the proposed solution is an attractive option for protecting the energy storage from DC link current pulsation. The dual active bridge converter combined with resonant controller can compensate the DC link current pulsation almost entirely.
This paper presents a system for compensating DC link current pulsation in four-wire inverters with energy storage operating under unbalanced load conditions. This phenomenon occurs when an inverter with an independent power control in each of the phases attempts to locally balance the voltage imbalance in the grid. Such a condition creates a DC link current pulsation, which is destructive for energy storage connected to the DC link. The conditions when this situation appears are presented in detail in the paper. A solution to this problem is proposed in the form of a dual active bridge converter and a capacitor bank to actively compensate this pulsation. The control algorithm is proposed based on a proportional-resonant controller. This paper presents the technical background and method by which the controller parameters were calculated, implemented and tested in a real-time system. The test results are presented and discussed, concluding that the proposed solution is an attractive option for protecting the energy storage from DC link current pulsation. The dual active bridge converter combined with resonant controller can compensate the DC link current pulsation almost entirely.
Record ID
Keywords
dual active bridge, Energy Storage, multi-resonant control, supercapacitor, three-phase four-wire converter
Subject
Suggested Citation
Zieliński D, Fatyga K. Dual Active Bridge as a DC Link Current Pulsation Compensator in Energy Storage Applications. (2023). LAPSE:2023.18948
Author Affiliations
Zieliński D: Department of Electrical Drives and Machines, Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, 20-618 Lublin, Poland [ORCID]
Fatyga K: Department of Electrical Drives and Machines, Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, 20-618 Lublin, Poland [ORCID]
Fatyga K: Department of Electrical Drives and Machines, Faculty of Electrical Engineering and Computer Science, Lublin University of Technology, 20-618 Lublin, Poland [ORCID]
Journal Name
Energies
Volume
14
Issue
19
First Page
6141
Year
2021
Publication Date
2021-09-27
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14196141, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.18948
This Record
External Link

https://doi.org/10.3390/en14196141
Publisher Version
Download
Meta
Record Statistics
Record Views
299
Version History
[v1] (Original Submission)
Mar 9, 2023
Verified by curator on
Mar 9, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
http://psecommunity.org/LAPSE:2023.18948
Record Owner
Auto Uploader for LAPSE
Links to Related Works
