LAPSE:2023.5822
Published Article

LAPSE:2023.5822
Flow Field Effect on the Performance of Direct Formic Acid Membraneless Fuel Cells: A Numerical Study
February 23, 2023
Abstract
The performance of both air-breathing and air-feeding direct formic acid membraneless fuel cells (DFAMFCs) possessing different flow fields were numerically investigated in this study at given concentration and flow rate for both fuel and electrolyte. Single serpentine, stepwise broadening serpentine, multi-serpentine and parallel channel were tested as liquid flow field, while single serpentine, stepwise broadening serpentine, multi-serpentine and pin channel were tested as air flow field. The channel width was either 0.8 mm or 1.3 mm. The simulation results showed that the air-breathing DFAMFC having identical flow field for both fuel and electrolyte yielded highest cell output. The air-breathing DFAMFC having SBS liquid flow field yielded a maximum power density of 10.5 mW/cm2, while the air-breathing DFAMFC having S(1.3) liquid flow field produced an open circuit voltage of 1.0 V owing to few formic acid penetration into the cathode. Concerning the air-feeding DFAMFCs, the DFAMFC having SBS liquid flow field and MS(0.8) air flow field yielded highest peak power density, 12 mW/cm2, at an airflow rate of 500 sccm. Considering the power generated by the DFAMFCs together with the power consumed by the air pump, DFAMFC having SBS liquid flow field and Pin(0.8) air flow field could be the preferred design.
The performance of both air-breathing and air-feeding direct formic acid membraneless fuel cells (DFAMFCs) possessing different flow fields were numerically investigated in this study at given concentration and flow rate for both fuel and electrolyte. Single serpentine, stepwise broadening serpentine, multi-serpentine and parallel channel were tested as liquid flow field, while single serpentine, stepwise broadening serpentine, multi-serpentine and pin channel were tested as air flow field. The channel width was either 0.8 mm or 1.3 mm. The simulation results showed that the air-breathing DFAMFC having identical flow field for both fuel and electrolyte yielded highest cell output. The air-breathing DFAMFC having SBS liquid flow field yielded a maximum power density of 10.5 mW/cm2, while the air-breathing DFAMFC having S(1.3) liquid flow field produced an open circuit voltage of 1.0 V owing to few formic acid penetration into the cathode. Concerning the air-feeding DFAMFCs, the DFAMFC having SBS liquid flow field and MS(0.8) air flow field yielded highest peak power density, 12 mW/cm2, at an airflow rate of 500 sccm. Considering the power generated by the DFAMFCs together with the power consumed by the air pump, DFAMFC having SBS liquid flow field and Pin(0.8) air flow field could be the preferred design.
Record ID
Keywords
flow field, formic acid, fuel cell, membraneless, Simulation
Subject
Suggested Citation
Shyu JC, Hung SH. Flow Field Effect on the Performance of Direct Formic Acid Membraneless Fuel Cells: A Numerical Study. (2023). LAPSE:2023.5822
Author Affiliations
Shyu JC: Department of Mechanical Engineering, National Kaohsiung University of Science and Technology, Kaohsiung 80778, Taiwan [ORCID]
Hung SH: Department of Mechanical Engineering, National Kaohsiung University of Science and Technology, Kaohsiung 80778, Taiwan
Hung SH: Department of Mechanical Engineering, National Kaohsiung University of Science and Technology, Kaohsiung 80778, Taiwan
Journal Name
Processes
Volume
9
Issue
5
First Page
746
Year
2021
Publication Date
2021-04-23
ISSN
2227-9717
Version Comments
Original Submission
Other Meta
PII: pr9050746, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.5822
This Record
External Link

https://doi.org/10.3390/pr9050746
Publisher Version
Download
Meta
Record Statistics
Record Views
228
Version History
[v1] (Original Submission)
Feb 23, 2023
Verified by curator on
Feb 23, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.5822
Record Owner
Auto Uploader for LAPSE
Links to Related Works