CFD Analysis of the Forced Airflow and Temperature Distribution in the Air-Conditioned Operator’s Cabin of the Stationary Rock Breaker in Underground Mine under Increasing Heat Flux
May 23, 2023
The exploitation of natural resources is associated with many natural hazards. Currently, the copper ore deposits exploited in Polish mines are located at a depth of about 1200 m below the surface. The primary temperature of the rocks in the exploited areas reaches 48 ∘C, which constitutes a major source of heat flux to the mine air. However, another important source of heat is the machine plant, which mainly consists of machines powered by diesel engines. Following the results of in situ measurements, boundary conditions for a simulation were determined and a geometric model of the cabin was created. Furthermore, an average human model was created, whose radiative heat transfer was included in the analysis. Three cases were studied: the first covering the current state of thermal conditions, based on the measurement results, and two cases of forecast conditions. In the second case, the temperature of the conditioned air was determined, and in the third, the flow velocity required to ensure thermal comfort was found. The results of the simulation indicated that for the microclimatic conditions established based on the measurements (ambient air temperature in the excavation 35.0 ∘C, air-conditioned airflow 2.4 × 10−2 m3/s, and temperature 10.0 ∘C), the temperature of the air inside the air-conditioned operator’s cabin would be 20.4 ∘C. Based on the personal mean vote (PMV) index, it was concluded that the thermal sensation would range from neutral to slightly cool, which confirmed the legitimacy of the actions taken to reduce the adverse impact of the microclimatic conditions on workers in the workplace. However, for the case of predicted conditions of enhanced heat flux from strata and machinery, resulting in an average ambient temperature increased to 38.0 ∘C, it would be necessary to lower the temperature of air from the air conditioner to 8.00 ∘C or increase the flow rate to 3.14 × 10−2 m3/s to maintain thermal comfort at the same level of PMV index.
Keywords
cabin air conditioning analysis, cabin interior, Computational Fluid Dynamics, heat transfer, thermal hazard
Suggested Citation
Wróblewski A, Macek A, Banasiewicz A, Gola S, Zawiślak M, Janicka A. CFD Analysis of the Forced Airflow and Temperature Distribution in the Air-Conditioned Operator’s Cabin of the Stationary Rock Breaker in Underground Mine under Increasing Heat Flux. (2023). LAPSE:2023.35751
Author Affiliations
Wróblewski A: Faculty of Geoengineering, Mining and Geology, Wroclaw University of Science and Technology, Na Grobli 15, 50-421 Wroclaw, Poland [ORCID]
Macek A: Faculty of Mechanical Engineering, Wroclaw University of Science and Technology, Łukasiewicza 5/7, 50-370 Wroclaw, Poland
Banasiewicz A: Faculty of Geoengineering, Mining and Geology, Wroclaw University of Science and Technology, Na Grobli 15, 50-421 Wroclaw, Poland [ORCID]
Gola S: Faculty of Geoengineering, Mining and Geology, Wroclaw University of Science and Technology, Na Grobli 15, 50-421 Wroclaw, Poland; KGHM Polska Miedź S.A., O/ZG Polkowice-Sieroszowice, 59-101 Kazimierzów, Poland [ORCID]
Zawiślak M: Faculty of Mechanical Engineering, Wroclaw University of Science and Technology, Łukasiewicza 5/7, 50-370 Wroclaw, Poland [ORCID]
Janicka A: Faculty of Mechanical Engineering, Wroclaw University of Science and Technology, Łukasiewicza 5/7, 50-370 Wroclaw, Poland [ORCID]
Journal Name
Energies
Volume
16
Issue
9
First Page
3814
Year
2023
Publication Date
2023-04-28
Published Version
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en16093814, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.35751
This Record
External Link

doi:10.3390/en16093814
Publisher Version
Download
Files
[Download 1v1.pdf] (3.9 MB)
May 23, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
118
Version History
[v1] (Original Submission)
May 23, 2023
 
Verified by curator on
May 23, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.35751
 
Original Submitter
Calvin Tsay
Links to Related Works
Directly Related to This Work
Publisher Version