Mutual Influence of External Wall Thermal Transmittance, Thermal Inertia, and Room Orientation on Office Thermal Comfort and Energy Demand
April 28, 2023
Abstract
Upgrades in building energy efficiency codes led to differences between buildings designed according to outdated codes and those with most recent requirements. In this context, our study investigates the influence of external wall thermal transmittance, thermal inertia, and orientation on energy demand (heating, cooling) and occupant thermal comfort. Simulation models of an office building were designed, varying (i) the thermal transmittance values (0.20 and 0.60 W/(m2K)), (ii) the room orientation (four cardinal directions), and (iii) the wall thermal inertia (approximately 60 kJ/(m2K) for low and 340 kJ/(m2K) for high thermal inertia. The energy demand for heating and cooling seasons was calculated for Ljubljana using EnergyPlus 9.0.0 software. The reduction of the external wall thermal transmittance value from 0.6 W/(m2K) to 0.2 W/(m2K) contributes to significant energy savings (63% for heating and 37% for cooling). Thermal inertia showed considerable potential for energy savings, especially in the cooling season (20% and 13%, depending on the external wall insulation level). In addition, the orientation proved to have a notable impact on heating and cooling demand, however not as pronounced as thermal inertia (up to 7% total energy demand). Comparison of the thermal comfort results showed that when internal air temperatures are identically controlled in all the rooms (i.e., internal air temperature is not an influencing factor), the external wall thermal transmittance, thermal inertia, and room orientation show negligible influence on the average occupant thermal comfort. The simultaneous achievement of thermally comfortable conditions in the working environment and low energy use can only be achieved by simultaneously considering the U-value and thermal inertia.
Upgrades in building energy efficiency codes led to differences between buildings designed according to outdated codes and those with most recent requirements. In this context, our study investigates the influence of external wall thermal transmittance, thermal inertia, and orientation on energy demand (heating, cooling) and occupant thermal comfort. Simulation models of an office building were designed, varying (i) the thermal transmittance values (0.20 and 0.60 W/(m2K)), (ii) the room orientation (four cardinal directions), and (iii) the wall thermal inertia (approximately 60 kJ/(m2K) for low and 340 kJ/(m2K) for high thermal inertia. The energy demand for heating and cooling seasons was calculated for Ljubljana using EnergyPlus 9.0.0 software. The reduction of the external wall thermal transmittance value from 0.6 W/(m2K) to 0.2 W/(m2K) contributes to significant energy savings (63% for heating and 37% for cooling). Thermal inertia showed considerable potential for energy savings, especially in the cooling season (20% and 13%, depending on the external wall insulation level). In addition, the orientation proved to have a notable impact on heating and cooling demand, however not as pronounced as thermal inertia (up to 7% total energy demand). Comparison of the thermal comfort results showed that when internal air temperatures are identically controlled in all the rooms (i.e., internal air temperature is not an influencing factor), the external wall thermal transmittance, thermal inertia, and room orientation show negligible influence on the average occupant thermal comfort. The simultaneous achievement of thermally comfortable conditions in the working environment and low energy use can only be achieved by simultaneously considering the U-value and thermal inertia.
Record ID
Keywords
energy demand, office building, orientation, thermal comfort, thermal inertia
Subject
Suggested Citation
Božiček D, Kunič R, Krainer A, Stritih U, Dovjak M. Mutual Influence of External Wall Thermal Transmittance, Thermal Inertia, and Room Orientation on Office Thermal Comfort and Energy Demand. (2023). LAPSE:2023.34960
Author Affiliations
Božiček D: Faculty of Civil and Geodetic Engineering, University of Ljubljana, Jamova Cesta 2, 1000 Ljubljana, Slovenia [ORCID]
Kunič R: Faculty of Civil and Geodetic Engineering, University of Ljubljana, Jamova Cesta 2, 1000 Ljubljana, Slovenia [ORCID]
Krainer A: Institute of Public and Environmental Health, 1000 Ljubljana, Slovenia
Stritih U: Faculty of Mechanical Engineering, University of Ljubljana, Aškrčeva Cesta 6, 1000 Ljubljana, Slovenia
Dovjak M: Faculty of Civil and Geodetic Engineering, University of Ljubljana, Jamova Cesta 2, 1000 Ljubljana, Slovenia [ORCID]
Kunič R: Faculty of Civil and Geodetic Engineering, University of Ljubljana, Jamova Cesta 2, 1000 Ljubljana, Slovenia [ORCID]
Krainer A: Institute of Public and Environmental Health, 1000 Ljubljana, Slovenia
Stritih U: Faculty of Mechanical Engineering, University of Ljubljana, Aškrčeva Cesta 6, 1000 Ljubljana, Slovenia
Dovjak M: Faculty of Civil and Geodetic Engineering, University of Ljubljana, Jamova Cesta 2, 1000 Ljubljana, Slovenia [ORCID]
Journal Name
Energies
Volume
16
Issue
8
First Page
3524
Year
2023
Publication Date
2023-04-18
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en16083524, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.34960
This Record
External Link

https://doi.org/10.3390/en16083524
Publisher Version
Download
Meta
Record Statistics
Record Views
182
Version History
[v1] (Original Submission)
Apr 28, 2023
Verified by curator on
Apr 28, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.34960
Record Owner
Auto Uploader for LAPSE
Links to Related Works