LAPSE:2023.10505
Published Article

LAPSE:2023.10505
Simulation and Exergoeconomic Analysis of a Trigeneration System Based on Biofuels from Spent Coffee Grounds
February 27, 2023
Abstract
Biofuels have become a source of renewable energy to offset the use of fossil fuels and meet the demand for electricity, heat, and cooling in the industrial sector. This study aims to (a) develop a simulation of a trigeneration system based on a gas turbine cycle and an absorption chiller unit, using biomass and syngas from spent coffee grounds (SCGs) to replace the conventional system currently supplying the energy requirements of an instant coffee plant located in Guayaquil, Ecuador, and (b) carry out an exergoeconomic analysis of the simulated system to compare the effects of different fuels. The results showed an increase in the exergetic efficiency from 51.9% to 84.5% when using a trigeneration system based on biomass instead of the conventional non-integrated system. Furthermore, the biomass-based system was found to have the lowest operating costs ($154.7/h) and the lowest heating, cooling, and power costs ($10.3/GJ, $20.2/GJ, and $23.4/GJ, respectively). Therefore, the results of this analysis reveal that using SCGs as biofuel in this instant coffee plant is feasible for producing steam, chilled water, and power.
Biofuels have become a source of renewable energy to offset the use of fossil fuels and meet the demand for electricity, heat, and cooling in the industrial sector. This study aims to (a) develop a simulation of a trigeneration system based on a gas turbine cycle and an absorption chiller unit, using biomass and syngas from spent coffee grounds (SCGs) to replace the conventional system currently supplying the energy requirements of an instant coffee plant located in Guayaquil, Ecuador, and (b) carry out an exergoeconomic analysis of the simulated system to compare the effects of different fuels. The results showed an increase in the exergetic efficiency from 51.9% to 84.5% when using a trigeneration system based on biomass instead of the conventional non-integrated system. Furthermore, the biomass-based system was found to have the lowest operating costs ($154.7/h) and the lowest heating, cooling, and power costs ($10.3/GJ, $20.2/GJ, and $23.4/GJ, respectively). Therefore, the results of this analysis reveal that using SCGs as biofuel in this instant coffee plant is feasible for producing steam, chilled water, and power.
Record ID
Subject
Suggested Citation
Tinoco Caicedo DL, Santos Torres M, Mero-Benavides M, Patiño Lopez O, Lozano Medina A, Blanco Marigorta AM. Simulation and Exergoeconomic Analysis of a Trigeneration System Based on Biofuels from Spent Coffee Grounds. (2023). LAPSE:2023.10505
Author Affiliations
Tinoco Caicedo DL: Centro de Energías Renovables y Alternativas (CERA), Escuela Superior Politécnica del Litoral Ecuador, Guayaquil 090903, Ecuador; Facultad de Ciencias Naturales y Matemáticas (FCNM), Escuela Superior Politécnica del Litoral Ecuador, Guayaquil 090903, [ORCID]
Santos Torres M: Facultad de Ciencias Naturales y Matemáticas (FCNM), Escuela Superior Politécnica del Litoral Ecuador, Guayaquil 090903, Ecuador [ORCID]
Mero-Benavides M: Facultad de Ciencias Naturales y Matemáticas (FCNM), Escuela Superior Politécnica del Litoral Ecuador, Guayaquil 090903, Ecuador [ORCID]
Patiño Lopez O: Facultad de Ciencias Naturales y Matemáticas (FCNM), Escuela Superior Politécnica del Litoral Ecuador, Guayaquil 090903, Ecuador [ORCID]
Lozano Medina A: Department of Process Engineering, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
Blanco Marigorta AM: Department of Process Engineering, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain [ORCID]
Santos Torres M: Facultad de Ciencias Naturales y Matemáticas (FCNM), Escuela Superior Politécnica del Litoral Ecuador, Guayaquil 090903, Ecuador [ORCID]
Mero-Benavides M: Facultad de Ciencias Naturales y Matemáticas (FCNM), Escuela Superior Politécnica del Litoral Ecuador, Guayaquil 090903, Ecuador [ORCID]
Patiño Lopez O: Facultad de Ciencias Naturales y Matemáticas (FCNM), Escuela Superior Politécnica del Litoral Ecuador, Guayaquil 090903, Ecuador [ORCID]
Lozano Medina A: Department of Process Engineering, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain
Blanco Marigorta AM: Department of Process Engineering, Universidad de Las Palmas de Gran Canaria, 35017 Las Palmas de Gran Canaria, Spain [ORCID]
Journal Name
Energies
Volume
16
Issue
4
First Page
1816
Year
2023
Publication Date
2023-02-11
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en16041816, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.10505
This Record
External Link

https://doi.org/10.3390/en16041816
Publisher Version
Download
Meta
Record Statistics
Record Views
372
Version History
[v1] (Original Submission)
Feb 27, 2023
Verified by curator on
Feb 27, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.10505
Record Owner
Auto Uploader for LAPSE
Links to Related Works
