LAPSE:2018.0172
Published Article
LAPSE:2018.0172
Discrete Blood Glucose Control in Diabetic Göttingen Minipigs
Berno J.E. Misgeld, Philipp G. Tenbrock, Katrin Lunze, Steffen Leonhardt
July 30, 2018
Despite continuous research effort, patients with type 1 diabetes mellitus (T1D) experience difficulties in daily adjustments of their blood glucose concentrations. New technological developments in the form of implanted intravenous infusion pumps and continuous blood glucose sensors might alleviate obstacles for the automatic adjustment of blood glucose concentration. These obstacles consist, for example, of large time-delays and insulin storage effects for the subcutaneous/interstitial route. Towards the goal of an artificial pancreas, we present a novel feedback controller approach that combines classical loop-shaping techniques with gain-scheduling and modern H ∞ -robust control approaches. A disturbance rejection design is proposed in discrete frequency domain based on the detailed model of the diabetic Göttingen minipig. The model is trimmed and linearised over a large operating range of blood glucose concentrations and insulin sensitivity values. Controller parameters are determined for each of these operating points. A discrete H ∞ loop-shaping compensator is designed to increase robustness of the artificial pancreas against general coprime factor uncertainty. The gain scheduled controller uses subcutaneous insulin injection as a control input and determines the controller input error from intravenous blood glucose concentration measurements, where parameter scheduling is achieved by an estimator of the insulin sensitivity parameter. Thus, only one controller stabilises a family of animal models. The controller is validated in silico with a total number of five Göttingen Minipig models, which were previously obtained by experimental identification procedures. Its performance is compared with an experimentally tested switching PI-controller.
Keywords
blood glucose control, discrete control, disturbance rejection, loop-shaping, robust control, type 1 diabetes mellitus
Suggested Citation
Misgeld BJ, Tenbrock PG, Lunze K, Leonhardt S. Discrete Blood Glucose Control in Diabetic Göttingen Minipigs. (2018). LAPSE:2018.0172
Author Affiliations
Misgeld BJ: Philips Chair for Medical Information Technology, RWTH Aachen University, Pauwelsstrasse 20, 52074 Aachen, Germany
Tenbrock PG: Philips Chair for Medical Information Technology, RWTH Aachen University, Pauwelsstrasse 20, 52074 Aachen, Germany
Lunze K: Philips Chair for Medical Information Technology, RWTH Aachen University, Pauwelsstrasse 20, 52074 Aachen, Germany
Leonhardt S: Philips Chair for Medical Information Technology, RWTH Aachen University, Pauwelsstrasse 20, 52074 Aachen, Germany [ORCID]
[Login] to see author email addresses.
Journal Name
Processes
Volume
4
Issue
3
Article Number
E22
Year
2016
Publication Date
2016-07-22
Published Version
ISSN
2227-9717
Version Comments
Original Submission
Other Meta
PII: pr4030022, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2018.0172
This Record
External Link

doi:10.3390/pr4030022
Publisher Version
Download
Files
[Download 1v1.pdf] (1.7 MB)
Jul 30, 2018
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
732
Version History
[v1] (Original Submission)
Jul 30, 2018
 
Verified by curator on
Jul 30, 2018
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2018.0172
 
Original Submitter
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version