LAPSE:2023.18056
Published Article

LAPSE:2023.18056
An Experimental Performance Evaluation for a Swirl-Vane Separator Using an Air-Water Test Facility
March 7, 2023
Abstract
The most important design parameters of a moisture separator to optimize the efficiency of a nuclear power plant are the moisture carry over and pressure drop. An air-water test facility was constructed to evaluate the design parameters for various types of conventional moisture separators in Korea. In this study, a half scale of swirl-vane separator was designed, and test conditions were defined based on the scaling law to cover a wide range of operating conditions. The moisture carry over was measured using an isokinetic sampling system for 34 different flow conditions. The MCO was in range of 0.30−7.05% according to the test conditions. Single and two-phase flow experiments were also carried out to identify the two-phase pressure drop characteristics. Based on the obtained results, the proposed empirical correlation model was extended to a submerged separator and applying these results to a full scale system is discussed in this paper.
The most important design parameters of a moisture separator to optimize the efficiency of a nuclear power plant are the moisture carry over and pressure drop. An air-water test facility was constructed to evaluate the design parameters for various types of conventional moisture separators in Korea. In this study, a half scale of swirl-vane separator was designed, and test conditions were defined based on the scaling law to cover a wide range of operating conditions. The moisture carry over was measured using an isokinetic sampling system for 34 different flow conditions. The MCO was in range of 0.30−7.05% according to the test conditions. Single and two-phase flow experiments were also carried out to identify the two-phase pressure drop characteristics. Based on the obtained results, the proposed empirical correlation model was extended to a submerged separator and applying these results to a full scale system is discussed in this paper.
Record ID
Keywords
moisture carry over, swirl-vane separator, two-phase pressure drop
Subject
Suggested Citation
Kim K, Kim WS, Lee JB. An Experimental Performance Evaluation for a Swirl-Vane Separator Using an Air-Water Test Facility. (2023). LAPSE:2023.18056
Author Affiliations
Journal Name
Energies
Volume
14
Issue
21
First Page
7072
Year
2021
Publication Date
2021-10-28
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14217072, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.18056
This Record
External Link

https://doi.org/10.3390/en14217072
Publisher Version
Download
Meta
Record Statistics
Record Views
192
Version History
[v1] (Original Submission)
Mar 7, 2023
Verified by curator on
Mar 7, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
http://psecommunity.org/LAPSE:2023.18056
Record Owner
Auto Uploader for LAPSE
Links to Related Works
