Simulation Research on Thermal Deviation in 700 °C Ultra-Supercritical Boiler
Zheng Kong, Jianquan Liu, Changxin Zhou
February 24, 2023
Abstract
Based on commercial CFD software, a 700 °C ultra-supercritical tangential boiler was simulated by the orthogonal test method, and the thermal deviation of flue gas at the furnace outlet section was used as the optimization index. Three horizontal optimization treatments are designed respectively for the air distribution mode of secondary air (factor A), the reverse tangent angle of the separate over-fire air (factor B), and the upper swing angle of the burner (factor C). The range analysis method, variance analysis method, and weight matrix analysis method are used to determine the factor and level combination of the best optimization effect and the weight of each factor. The research results show that the significance of the influence of each factor on the optimization index is: B > C > A (reverse tangent angle of the separate over-fire air > the upper swing angle of the burner > the secondary air distribution mode); the weight ratios of the three factors are: factor A is 0.080, factor B is 0.543, and factor C is 0.241; based on the three analysis methods, it is concluded that factor B has a highly significant impact on the optimization index, factor C has an impact on the optimization index, and factor A has no impact on the optimization index, and it is determined that the optimal factor and level combination of the orthogonal test is A1B3C3. Under this combination, the thermal deviation in the furnace is 1.349 K, and the problem of thermal deviation is basically eliminated, being 116.066 K lower than the highest thermal deviation of 117.415 K, which is very obvious.
Keywords
700 °C ultra-supercritical boiler, orthogonal test method, range analysis method, thermal deviation, variance analysis method, weight matrix analysis method
Suggested Citation
Kong Z, Liu J, Zhou C. Simulation Research on Thermal Deviation in 700 °C Ultra-Supercritical Boiler. (2023). LAPSE:2023.8755
Author Affiliations
Kong Z: College of Energy and Mechanical Engineering, Shanghai University of Electric Power, Shanghai 201306, China [ORCID]
Liu J: College of Energy and Mechanical Engineering, Shanghai University of Electric Power, Shanghai 201306, China
Zhou C: College of Energy and Mechanical Engineering, Shanghai University of Electric Power, Shanghai 201306, China
Journal Name
Energies
Volume
15
Issue
20
First Page
7596
Year
2022
Publication Date
2022-10-14
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15207596, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.8755
This Record
External Link

https://doi.org/10.3390/en15207596
Publisher Version
Download
Files
Feb 24, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
178
Version History
[v1] (Original Submission)
Feb 24, 2023
 
Verified by curator on
Feb 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.8755
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version
(0.19 seconds)