Modern healthcare is transforming from hospital-centric to individual-centric systems. Emerging implantable and wearable medical (IWM) devices are integral parts of enabling affordable and accessible healthcare. Early disease diagnosis and preventive measures are possible by continuously monitoring clinically significant physiological parameters. However, most IWM devices are battery-operated, requiring replacement, which interrupts the proper functioning of these devices. For the continuous operation of medical devices for an extended period of time, supplying uninterrupted energy is crucial. A sustainable and health-compatible energy supply will ensure the high-performance real-time functioning of IWM devices and prolong their lifetime. Therefore, harvesting energy from the human body and ambient environment is necessary for enduring precision healthcare and maximizing user comfort. Energy harvesters convert energy from various sources into an equivalent electrical form. This paper presents a state-of-the-art comprehensive review of energy harvesting techniques focusing on medical applications. Various energy harvesting approaches, working principles, and the current state are discussed. In addition, the advantages and limitations of different methods are analyzed and existing challenges and prospects for improvement are outlined. This paper will help with understanding the energy harvesting technologies for the development of high-efficiency, reliable, robust, and battery-free portable medical devices.
Modern healthcare is transforming from hospital-centric to individual-centric systems. Emerging implantable and wearable medical (IWM) devices are integral parts of enabling affordable and accessible healthcare. Early disease diagnosis and preventive measures are possible by continuously monitoring clinically significant physiological parameters. However, most IWM devices are battery-operated, requiring replacement, which interrupts the proper functioning of these devices. For the continuous operation of medical devices for an extended period of time, supplying uninterrupted energy is crucial. A sustainable and health-compatible energy supply will ensure the high-performance real-time functioning of IWM devices and prolong their lifetime. Therefore, harvesting energy from the human body and ambient environment is necessary for enduring precision healthcare and maximizing user comfort. Energy harvesters convert energy from various sources into an equivalent electrical form. This paper presents a state-of-the-art comprehensive review of energy harvesting techniques focusing on medical applications. Various energy harvesting approaches, working principles, and the current state are discussed. In addition, the advantages and limitations of different methods are analyzed and existing challenges and prospects for improvement are outlined. This paper will help with understanding the energy harvesting technologies for the development of high-efficiency, reliable, robust, and battery-free portable medical devices.
Record ID
Keywords
biocompatibility, energy harvesting, health monitoring, maximum power point tracking, medical implants, precision medicine, wearable sensors, wireless power transfer
Subject
Suggested Citation
Shuvo MMH, Titirsha T, Amin N, Islam SK. Energy Harvesting in Implantable and Wearable Medical Devices for Enduring Precision Healthcare. (2023). LAPSE:2023.8662v1
Author Affiliations
Shuvo MMH: Analog/Mixed Signal VLSI and Devices Laboratory, Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO 65211, USA [ORCID]
Titirsha T: Analog/Mixed Signal VLSI and Devices Laboratory, Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO 65211, USA [ORCID]
Amin N: Analog/Mixed Signal VLSI and Devices Laboratory, Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO 65211, USA [ORCID]
Islam SK: Analog/Mixed Signal VLSI and Devices Laboratory, Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO 65211, USA [ORCID]
Titirsha T: Analog/Mixed Signal VLSI and Devices Laboratory, Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO 65211, USA [ORCID]
Amin N: Analog/Mixed Signal VLSI and Devices Laboratory, Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO 65211, USA [ORCID]
Islam SK: Analog/Mixed Signal VLSI and Devices Laboratory, Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO 65211, USA [ORCID]
Journal Name
Energies
Volume
15
Issue
20
First Page
7495
Year
2022
Publication Date
2022-10-12
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15207495, Publication Type: Review
Record Map
Published Article

LAPSE:2023.8662v1
This Record
External Link

https://doi.org/10.3390/en15207495
Publisher Version
Download
Meta
Record Statistics
Record Views
391
Version History
[v1] (Original Submission)
Feb 24, 2023
Verified by curator on
Feb 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.8662v1
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.08 seconds)
[0.08 s]