LAPSE:2023.8366
Published Article

LAPSE:2023.8366
Torque Control for PMSG-Based Wind-Power System Using Stationary abc-Reference Frame
February 24, 2023
Abstract
The power system of wind farms is generally characterized by a weak grid, in which voltages may be heavily distorted and imbalanced, challenging the control scheme of wind-power converters that must be impervious to such disturbances. The control scheme in the stationary natural abc-frame has shown good performance under non-ideal voltage conditions, and then this paper proposes to analyze the operational performance of a wind-power system based on a permanent magnet synchronous generator subject to non-ideal conditions of the grid voltage, with its control scheme devised in the abc-reference frame. The proposed control scheme considers the torque control decoupling the flux and torque for the generator-side, showing the possibility to implement the machine torque control, without any coordinates transformation using a closed loop dot-product approach, between the field flux and stator currents. For the grid-side converter, the load current compensation is proposed, using the load current decomposition and conservative power theory (CPT), improving the grid power quality. The simulation results estimate the performance of the grid-side control under distorted and asymmetrical voltages, and the generator-side control against torque disturbances due to wind speed variation. Finally, experimental results in a small-scale test bench validate the proposed control scheme in injecting active and reactive power into the grid, and the torque control under wind speed variation.
The power system of wind farms is generally characterized by a weak grid, in which voltages may be heavily distorted and imbalanced, challenging the control scheme of wind-power converters that must be impervious to such disturbances. The control scheme in the stationary natural abc-frame has shown good performance under non-ideal voltage conditions, and then this paper proposes to analyze the operational performance of a wind-power system based on a permanent magnet synchronous generator subject to non-ideal conditions of the grid voltage, with its control scheme devised in the abc-reference frame. The proposed control scheme considers the torque control decoupling the flux and torque for the generator-side, showing the possibility to implement the machine torque control, without any coordinates transformation using a closed loop dot-product approach, between the field flux and stator currents. For the grid-side converter, the load current compensation is proposed, using the load current decomposition and conservative power theory (CPT), improving the grid power quality. The simulation results estimate the performance of the grid-side control under distorted and asymmetrical voltages, and the generator-side control against torque disturbances due to wind speed variation. Finally, experimental results in a small-scale test bench validate the proposed control scheme in injecting active and reactive power into the grid, and the torque control under wind speed variation.
Record ID
Keywords
abc-frame control, distributed generation system, permanent magnet synchronous generator, torque control, wind-power system
Subject
Suggested Citation
da Costa IDL, Brandao DI, Seleme SI Jr, Morais LMF. Torque Control for PMSG-Based Wind-Power System Using Stationary abc-Reference Frame. (2023). LAPSE:2023.8366
Author Affiliations
da Costa IDL: Graduate Program in Electrical Engineering, Universidade Federal de Minas Gerais (UFMG), Antônio Carlos 6627, Belo Horizonte 31270-901, MG, Brazil [ORCID]
Brandao DI: Graduate Program in Electrical Engineering, Universidade Federal de Minas Gerais (UFMG), Antônio Carlos 6627, Belo Horizonte 31270-901, MG, Brazil [ORCID]
Seleme SI Jr: Graduate Program in Electrical Engineering, Universidade Federal de Minas Gerais (UFMG), Antônio Carlos 6627, Belo Horizonte 31270-901, MG, Brazil
Morais LMF: Graduate Program in Electrical Engineering, Universidade Federal de Minas Gerais (UFMG), Antônio Carlos 6627, Belo Horizonte 31270-901, MG, Brazil [ORCID]
Brandao DI: Graduate Program in Electrical Engineering, Universidade Federal de Minas Gerais (UFMG), Antônio Carlos 6627, Belo Horizonte 31270-901, MG, Brazil [ORCID]
Seleme SI Jr: Graduate Program in Electrical Engineering, Universidade Federal de Minas Gerais (UFMG), Antônio Carlos 6627, Belo Horizonte 31270-901, MG, Brazil
Morais LMF: Graduate Program in Electrical Engineering, Universidade Federal de Minas Gerais (UFMG), Antônio Carlos 6627, Belo Horizonte 31270-901, MG, Brazil [ORCID]
Journal Name
Energies
Volume
15
Issue
21
First Page
8060
Year
2022
Publication Date
2022-10-29
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15218060, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.8366
This Record
External Link

https://doi.org/10.3390/en15218060
Publisher Version
Download
Meta
Record Statistics
Record Views
180
Version History
[v1] (Original Submission)
Feb 24, 2023
Verified by curator on
Feb 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.8366
Record Owner
Auto Uploader for LAPSE
Links to Related Works
