Influencing Factors of a Cooling System Based on Low-Temperature Mine Water as a Direct Cooling Source
February 24, 2023
Abstract
With the depletion of shallow metal mineral resources, deep mining has become more common. In the process of deep mining, heat hazards in mines seriously threaten the health of personnel and the safety of mining operations. According to the flow and low-temperature characteristics of abundant water in Maoping Lead Zinc Mine, this paper proposes the direct use of the low-temperature water inflow of the mine as the cold source by which to conduct the heat exchange with a single spiral-tube heat exchanger for mine cooling. An experimental platform was built for the cooling system to allow us to explore the mechanism of the influence of the inlet air volume and air temperature and the inlet water temperature and flow on the cooling effect of the single spiral-tube heat exchanger. It was found that with the increase in the inlet air volume and inlet water temperature, the cooling efficiency of the heat exchanger decreased, while with the increase in the inlet air temperature, the cooling efficiency of the heat exchanger increased. Within the experimental range, 127.2 m3/h was found to be the optimum inlet air volume, and 33.0 °C was the most appropriate inlet air temperature; the water temperature of Maoping Coal Mine is about 20 °C throughout the year, and the industrial test site can reduce the wind temperature of 31.5 °C to 23.9 °C. The inlet water flow is positively related to the cooling effect. With the increase in the water flow, the outlet temperature of the air flow at each working point was continuously reduced, and the cooling effect of the heat exchanger was improved. The moisture content of the inlet air flow can be reduced by increasing the low-temperature inlet water flow. Through experiments, the feasibility of the cooling system that directly uses the mine’s low-temperature water as the cold source was verified. A multiple linear regression analysis equation for the cooling system model is proposed, which provides a reference for formulating effective measures to prevent and control heat hazards in mines.
With the depletion of shallow metal mineral resources, deep mining has become more common. In the process of deep mining, heat hazards in mines seriously threaten the health of personnel and the safety of mining operations. According to the flow and low-temperature characteristics of abundant water in Maoping Lead Zinc Mine, this paper proposes the direct use of the low-temperature water inflow of the mine as the cold source by which to conduct the heat exchange with a single spiral-tube heat exchanger for mine cooling. An experimental platform was built for the cooling system to allow us to explore the mechanism of the influence of the inlet air volume and air temperature and the inlet water temperature and flow on the cooling effect of the single spiral-tube heat exchanger. It was found that with the increase in the inlet air volume and inlet water temperature, the cooling efficiency of the heat exchanger decreased, while with the increase in the inlet air temperature, the cooling efficiency of the heat exchanger increased. Within the experimental range, 127.2 m3/h was found to be the optimum inlet air volume, and 33.0 °C was the most appropriate inlet air temperature; the water temperature of Maoping Coal Mine is about 20 °C throughout the year, and the industrial test site can reduce the wind temperature of 31.5 °C to 23.9 °C. The inlet water flow is positively related to the cooling effect. With the increase in the water flow, the outlet temperature of the air flow at each working point was continuously reduced, and the cooling effect of the heat exchanger was improved. The moisture content of the inlet air flow can be reduced by increasing the low-temperature inlet water flow. Through experiments, the feasibility of the cooling system that directly uses the mine’s low-temperature water as the cold source was verified. A multiple linear regression analysis equation for the cooling system model is proposed, which provides a reference for formulating effective measures to prevent and control heat hazards in mines.
Record ID
Keywords
heat exchange efficiency, low-temperature water inflow, mine heat hazard, single spiral-tube heat exchanger
Subject
Suggested Citation
Jiang H, Cui S, Mu X, Tang L, Wang Y, Jian C, Chen C. Influencing Factors of a Cooling System Based on Low-Temperature Mine Water as a Direct Cooling Source. (2023). LAPSE:2023.7516
Author Affiliations
Jiang H: Yiliang Chihong Mining Co., Ltd., Zhaotong 657000, China
Cui S: Yiliang Chihong Mining Co., Ltd., Zhaotong 657000, China
Mu X: Yiliang Chihong Mining Co., Ltd., Zhaotong 657000, China
Tang L: Yiliang Chihong Mining Co., Ltd., Zhaotong 657000, China
Wang Y: School of Safety Engineering, China University of Mining and Technology, Xuzhou 221116, China [ORCID]
Jian C: School of Safety Engineering, China University of Mining and Technology, Xuzhou 221116, China
Chen C: School of Safety Engineering, China University of Mining and Technology, Xuzhou 221116, China
Cui S: Yiliang Chihong Mining Co., Ltd., Zhaotong 657000, China
Mu X: Yiliang Chihong Mining Co., Ltd., Zhaotong 657000, China
Tang L: Yiliang Chihong Mining Co., Ltd., Zhaotong 657000, China
Wang Y: School of Safety Engineering, China University of Mining and Technology, Xuzhou 221116, China [ORCID]
Jian C: School of Safety Engineering, China University of Mining and Technology, Xuzhou 221116, China
Chen C: School of Safety Engineering, China University of Mining and Technology, Xuzhou 221116, China
Journal Name
Energies
Volume
15
Issue
23
First Page
9071
Year
2022
Publication Date
2022-11-30
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15239071, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.7516
This Record
External Link

https://doi.org/10.3390/en15239071
Publisher Version
Download
Meta
Record Statistics
Record Views
372
Version History
[v1] (Original Submission)
Feb 24, 2023
Verified by curator on
Feb 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.7516
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.17 seconds)
[0.17 s]