Analysis of an Evaporative Condensation System Coupled to a Microchannel-Separated Heat Pipe for Data Centers
February 24, 2023
Abstract
In the age of the digital economy, the data center is the most crucial piece of infrastructure. The issue of the excessive power consumption of a data center’s cooling system needs to be addressed as the national objective of “peak carbon and carbon neutrality” is increasingly promoted. In this study, a microchannel-separated heat pipe-cooling system with evaporative condensation is introduced. The system may switch between three modes of operation in response to changes in outdoor air quality parameters, thereby maximizing the utilization of natural cooling sources while lowering data centers’ cooling costs. The purpose of this paper is to analyze the energy-saving potential of the hybrid system through experimental tests. The results show that 114.4% is the ideal liquid-loading rate for the heat pipe system. Under working conditions in Xi’an, the annual operating hours of the three modes accounted for 47.2%, 6.1%, and 46.7%. The hybrid cooling system may save 62.04% of the energy used annually compared to the standard cooling system and the cooling system in the server room thanks to its yearly average COP of 9.43.
In the age of the digital economy, the data center is the most crucial piece of infrastructure. The issue of the excessive power consumption of a data center’s cooling system needs to be addressed as the national objective of “peak carbon and carbon neutrality” is increasingly promoted. In this study, a microchannel-separated heat pipe-cooling system with evaporative condensation is introduced. The system may switch between three modes of operation in response to changes in outdoor air quality parameters, thereby maximizing the utilization of natural cooling sources while lowering data centers’ cooling costs. The purpose of this paper is to analyze the energy-saving potential of the hybrid system through experimental tests. The results show that 114.4% is the ideal liquid-loading rate for the heat pipe system. Under working conditions in Xi’an, the annual operating hours of the three modes accounted for 47.2%, 6.1%, and 46.7%. The hybrid cooling system may save 62.04% of the energy used annually compared to the standard cooling system and the cooling system in the server room thanks to its yearly average COP of 9.43.
Record ID
Keywords
data center, evaporative condensation, microchannel separate heat pipe, performance test
Subject
Suggested Citation
Wang Y, Huang X, Chu J, Du Y, Tang X, Dai C, Ma G. Analysis of an Evaporative Condensation System Coupled to a Microchannel-Separated Heat Pipe for Data Centers. (2023). LAPSE:2023.7503
Author Affiliations
Wang Y: School of Urban Planning and Municipal Engineering, Xi’an Polytechnic University, Xi’an 710048, China
Huang X: School of Urban Planning and Municipal Engineering, Xi’an Polytechnic University, Xi’an 710048, China
Chu J: School of Urban Planning and Municipal Engineering, Xi’an Polytechnic University, Xi’an 710048, China [ORCID]
Du Y: School of Urban Planning and Municipal Engineering, Xi’an Polytechnic University, Xi’an 710048, China
Tang X: BLUE-ON (Jiangsu) Environmental SYSTEM Co., Ltd., Taixing 225441, China
Dai C: School of Urban Planning and Municipal Engineering, Xi’an Polytechnic University, Xi’an 710048, China
Ma G: School of Urban Planning and Municipal Engineering, Xi’an Polytechnic University, Xi’an 710048, China
Huang X: School of Urban Planning and Municipal Engineering, Xi’an Polytechnic University, Xi’an 710048, China
Chu J: School of Urban Planning and Municipal Engineering, Xi’an Polytechnic University, Xi’an 710048, China [ORCID]
Du Y: School of Urban Planning and Municipal Engineering, Xi’an Polytechnic University, Xi’an 710048, China
Tang X: BLUE-ON (Jiangsu) Environmental SYSTEM Co., Ltd., Taixing 225441, China
Dai C: School of Urban Planning and Municipal Engineering, Xi’an Polytechnic University, Xi’an 710048, China
Ma G: School of Urban Planning and Municipal Engineering, Xi’an Polytechnic University, Xi’an 710048, China
Journal Name
Energies
Volume
15
Issue
23
First Page
9056
Year
2022
Publication Date
2022-11-30
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15239056, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.7503
This Record
External Link

https://doi.org/10.3390/en15239056
Publisher Version
Download
Meta
Record Statistics
Record Views
345
Version History
[v1] (Original Submission)
Feb 24, 2023
Verified by curator on
Feb 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.7503
Record Owner
Auto Uploader for LAPSE
Links to Related Works