LAPSE:2023.3963
Published Article
LAPSE:2023.3963
Influence of Single/Dual Ventilation Path on Fluid Field and Temperature Field of HVLSSR-PMSM with Air-Cooled Hybrid Ventilation Systems
Zhaobin Cao, Weili Li, Xiaochen Zhang, Yu Fan, Jianjun Zeng
February 22, 2023
Abstract
Due to the solid rotor structure, High-Voltage Line-Start Solid Rotor Permanent Magnet Synchronous Motor (HVLSSR-PMSM) operates with high rotor temperature rise. If the ventilation path cannot take the rotor heat away in time, the rotor will overheat or even may led to the thermal demagnetization for permanent magnet. Therefore, it is of great significance to study the thermal issues of HVLSSR-PMSM. In the paper, the fluid field and temperature field of a 315 kW, 6 kV HVLSSR-PMSM with air-cooled hybrid ventilation systems are investigated. Firstly, the electromagnetic analysis of the machine is done by using the finite-element method, the loss distributions then are obtained, which will be assigned as the heat source for thermal analysis. Then, the three -dimensional (3-D) fluid thermal coupled mathematical model for thermal analysis of HVLSSR-PMSM is established. The temperature field and the fluid flowing state of HVLSSR-PMSM with single ventilation path air-cooled system are investigated by using the established 3D fluid thermal coupled mathematical model. A dual ventilation path air-cooled system for HVLSSR-PMSM is proposed to reduce the operating temperature rise. Then, the temperature field and fluid field of HVLSSR-PMSM with dual ventilation system are analyzed by comparing with single ventilation system. Moreover, the temperature experiments are carried out on the machine with dual ventilation system to validate the accuracy of the established mathematical models. The results show that the proposed dual ventilation path air-cooled system can effectively improve the thermal distribution of HVLSSR-PMSM, whilst it can also reduce the working temperature rise of the machine.
Keywords
air ventilation system, line-start, permanent magnet synchronous motor, solid rotor, three-dimensional fluid thermal coupled model
Subject
Suggested Citation
Cao Z, Li W, Zhang X, Fan Y, Zeng J. Influence of Single/Dual Ventilation Path on Fluid Field and Temperature Field of HVLSSR-PMSM with Air-Cooled Hybrid Ventilation Systems. (2023). LAPSE:2023.3963
Author Affiliations
Cao Z: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China [ORCID]
Li W: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
Zhang X: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
Fan Y: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
Zeng J: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China; School of Electrical and Automation Engineering, East China Jiaotong University, Nanchang 330013, China
[Login] to see author email addresses.
Journal Name
Energies
Volume
11
Issue
6
Article Number
E1343
Year
2018
Publication Date
2018-05-25
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en11061343, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.3963
This Record
External Link

https://doi.org/10.3390/en11061343
Publisher Version
Download
Files
Feb 22, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
368
Version History
[v1] (Original Submission)
Feb 22, 2023
 
Verified by curator on
Feb 22, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.3963
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version
(0.07 seconds)

[0.07 s]