LAPSE:2023.3578
Published Article

LAPSE:2023.3578
Comparative Study on Boiling Heat Transfer Characteristics and Performance of Low-Temperature Heating System of R744 and Its Azeotropic Refrigerant
February 22, 2023
Abstract
R744 is the most competitive and ideal natural refrigerant when flammability and toxicity are strictly limited. However, there are still some problems when it is applied to a heating system. For example, the discharge pressure of the system exceeds 10 MPa, it increases the cost of the system, and the cycle efficiency is also low. To solve these problems, this paper proposes to replace R744 by mixing R744 and ethane at a ratio of (77.6/22.4) to form an azeotropic refrigerant. At present, there is little research on R744 azeotropic refrigerant. Therefore, this paper first establishes the CFD model and compiles the UDF program to focus on flow boiling heat transfer characteristics, and then, it analyzes the performance of R744 and its azeotropic refrigerant in a low-temperature heating system. The results show that the heat transfer coefficient of R744 and its azeotropic refrigerant decreases with an increase in mass flux and increases with an increase in heat flux and saturation temperature; the heat transfer coefficient of azeotropic refrigerant is greater than R744; and there is no dryness under the same conditions. Under a given operating condition, there is a critical point that makes the performance of azeotropic refrigerant better than R744, and this critical point is related to the outlet temperature of a gas cooler, and the system discharge temperature of azeotropic refrigerant is significantly lower than that of R744. In conclusion, azeotropic refrigerant has certain advantages in heat transfer and system performance compared with R744, which will also play an important role in promoting the replacement of refrigerant in the future.
R744 is the most competitive and ideal natural refrigerant when flammability and toxicity are strictly limited. However, there are still some problems when it is applied to a heating system. For example, the discharge pressure of the system exceeds 10 MPa, it increases the cost of the system, and the cycle efficiency is also low. To solve these problems, this paper proposes to replace R744 by mixing R744 and ethane at a ratio of (77.6/22.4) to form an azeotropic refrigerant. At present, there is little research on R744 azeotropic refrigerant. Therefore, this paper first establishes the CFD model and compiles the UDF program to focus on flow boiling heat transfer characteristics, and then, it analyzes the performance of R744 and its azeotropic refrigerant in a low-temperature heating system. The results show that the heat transfer coefficient of R744 and its azeotropic refrigerant decreases with an increase in mass flux and increases with an increase in heat flux and saturation temperature; the heat transfer coefficient of azeotropic refrigerant is greater than R744; and there is no dryness under the same conditions. Under a given operating condition, there is a critical point that makes the performance of azeotropic refrigerant better than R744, and this critical point is related to the outlet temperature of a gas cooler, and the system discharge temperature of azeotropic refrigerant is significantly lower than that of R744. In conclusion, azeotropic refrigerant has certain advantages in heat transfer and system performance compared with R744, which will also play an important role in promoting the replacement of refrigerant in the future.
Record ID
Keywords
2D model, azeotropic refrigerant, boiling heat transfer, COP, R744, refrigerant replacement
Subject
Suggested Citation
Sun D, Zhang X, Liu Z, Zhang H. Comparative Study on Boiling Heat Transfer Characteristics and Performance of Low-Temperature Heating System of R744 and Its Azeotropic Refrigerant. (2023). LAPSE:2023.3578
Author Affiliations
Sun D: School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China
Zhang X: School of Energy and Power Engineering, Northeast Electric Power University, Jilin 132000, China
Liu Z: School of Energy and Power Engineering, Northeast Electric Power University, Jilin 132000, China
Zhang H: School of Energy and Power Engineering, Northeast Electric Power University, Jilin 132000, China
Zhang X: School of Energy and Power Engineering, Northeast Electric Power University, Jilin 132000, China
Liu Z: School of Energy and Power Engineering, Northeast Electric Power University, Jilin 132000, China
Zhang H: School of Energy and Power Engineering, Northeast Electric Power University, Jilin 132000, China
Journal Name
Energies
Volume
16
Issue
3
First Page
1313
Year
2023
Publication Date
2023-01-26
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en16031313, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.3578
This Record
External Link

https://doi.org/10.3390/en16031313
Publisher Version
Download
Meta
Record Statistics
Record Views
214
Version History
[v1] (Original Submission)
Feb 22, 2023
Verified by curator on
Feb 22, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.3578
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.2 seconds)