LAPSE:2023.35194
Published Article
LAPSE:2023.35194
Techniques Used for Bond Strengthening of Sub-Standard Splices in Concrete: A Review Study
Sabry Fayed, Walid Mansour, Taher A. Tawfik, Peter Sabol, Dušan Katunský
April 28, 2023
Bar splicing is considered an essential part of the construction process of reinforced concrete (RC) due to the ease of installation in construction, transportation constraints, and restricted length of reinforcing bars. Splices serve the primary role of joining reinforcement bars in standard RC elements such as columns, walls, beams, slabs, and joints. Bond behavior between the bars and the concrete is one of the fundamental qualities required for appropriate RC structure design and analysis, as it affects serviceability and ultimate limit states. The most common failure found in lap splice locations is debonding, which occurs at the splice region and insufficient lapped length is considered as the primary cause because of design or construction mistakes, design by outmoded code, and natural catastrophes. As a result, strengthening existing substandard splices in RC structures is critical. The purpose of this research is to analyze and summarize experimental strengthening solutions for inadequate splices. The most common methods are confining spirals, confining with internal or external steel stirrups or carbon fiber reinforced polymer (CFRP), concrete jacketing, fiber reinforced polymers (FRP), post-tensioning prestressed RC, external confining with CFRP, near surface mounted (NSM) techniques, ultra-high-performance concrete (UHPC), fiber reinforced concrete (FRC) and combinations of two methods. Each method of strengthening is evaluated based on its performance, benefits, drawbacks, application-specific elements, and variables influencing the design and scope of applicability. A comparison of the key methodologies was also carried out. The most recent studies and recommendations for improving inadequate lapped splices are provided.
Keywords
bond failure, bond strength, bonded length, CFRP, confinement, insufficient lap splice length, jacketing, RC members, review, strengthening methods, UHPC
Suggested Citation
Fayed S, Mansour W, Tawfik TA, Sabol P, Katunský D. Techniques Used for Bond Strengthening of Sub-Standard Splices in Concrete: A Review Study. (2023). LAPSE:2023.35194
Author Affiliations
Fayed S: Civil Engineering Department, Faculty of Engineering, Kafrelsheikh University, Kafr El Sheikh 33516, Egypt
Mansour W: Civil Engineering Department, Faculty of Engineering, Kafrelsheikh University, Kafr El Sheikh 33516, Egypt [ORCID]
Tawfik TA: Department of Construction and Building Engineering, High Institute of Engineering, October 6 City 12585, Egypt; Institute of Construction and Architecture, Slovak Academy of Sciences, Dúbravská cesta 9, 84503 Bratislava, Slovakia [ORCID]
Sabol P: Center for Research and Innovation in Construction, Technical University of Košice, 04200 Košice, Slovakia
Katunský D: Institute of Architectural Engineering, Technical University of Košice, 04200 Košice, Slovakia [ORCID]
Journal Name
Processes
Volume
11
Issue
4
First Page
1119
Year
2023
Publication Date
2023-04-05
Published Version
ISSN
2227-9717
Version Comments
Original Submission
Other Meta
PII: pr11041119, Publication Type: Review
Record Map
Published Article

LAPSE:2023.35194
This Record
External Link

doi:10.3390/pr11041119
Publisher Version
Download
Files
[Download 1v1.pdf] (3.5 MB)
Apr 28, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
92
Version History
[v1] (Original Submission)
Apr 28, 2023
 
Verified by curator on
Apr 28, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.35194
 
Original Submitter
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version