Endurance of Polymeric Insulation Foil Exposed to DC-Biased Medium-Frequency Rectangular Pulse Voltage Stress
April 25, 2023
The endurance of polymeric insulation foil is investigated under a mixed medium-voltage stress (DC + medium-frequency rectangular pulse) by means of accelerated lifetime testing. A dedicated setup is used that allows us to selectively eliminate the known risk factors for premature insulation failure under medium-frequency pulse voltage stress: partial discharges (PDs) during pulse transitions, excessive dielectric heating, and systemic overvoltages. The obtained results on polyethylenterephtalat (PET) insulation foil suggest that the adequate consideration of these factors is sufficient for eliminating the adverse effects of the pulse modulation under the investigated conditions. Indeed, if all mentioned risk factors are eliminated, the time to failure observed under a pure DC stress is shorter than with a superimposed pulse (keeping the same peak voltage). There is then no indication of an additional detrimental “per pulse” degradation process (i.e., the time to failure is not dependent on pulse frequency). In contrast, when repetitive PDs are present, the lifetime under combined DC + rectangular pulse stress strongly decreases with increasing pulse switching frequency. PD erosion of the foil is quantified by means of confocal microscopy, and the applicability of the streamer criterion for predicting PD inception is discussed.
Keywords
aging, converter, dry-type insulation, electromechanical stress, inverter, medium-frequency, partial discharge, power electronics, pulse-width-modulated (PWM), time to failure
Subject
Suggested Citation
Färber R, Guillod T, Krismer F, Kolar JW, Franck CM. Endurance of Polymeric Insulation Foil Exposed to DC-Biased Medium-Frequency Rectangular Pulse Voltage Stress. (2023). LAPSE:2023.34186
Author Affiliations
Färber R: High Voltage Laboratory (HVL), Department of Information Technology and Electrical Engineering, ETH Zürich, 8092 Zürich, Switzerland [ORCID]
Guillod T: Power Electronic Systems Laboratory (PES), Department of Information Technology and Electrical Engineering, ETH Zürich, 8092 Zürich, Switzerland [ORCID]
Krismer F: Power Electronic Systems Laboratory (PES), Department of Information Technology and Electrical Engineering, ETH Zürich, 8092 Zürich, Switzerland [ORCID]
Kolar JW: Power Electronic Systems Laboratory (PES), Department of Information Technology and Electrical Engineering, ETH Zürich, 8092 Zürich, Switzerland [ORCID]
Franck CM: High Voltage Laboratory (HVL), Department of Information Technology and Electrical Engineering, ETH Zürich, 8092 Zürich, Switzerland [ORCID]
Journal Name
Energies
Volume
13
Issue
1
Article Number
E13
Year
2019
Publication Date
2019-12-18
Published Version
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13010013, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.34186
This Record
External Link

doi:10.3390/en13010013
Publisher Version
Download
Files
[Download 1v1.pdf] (6.6 MB)
Apr 25, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
65
Version History
[v1] (Original Submission)
Apr 25, 2023
 
Verified by curator on
Apr 25, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.34186
 
Original Submitter
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version