LAPSE:2023.30587
Published Article

LAPSE:2023.30587
Influence of the Selection of the Core Shape and Winding Arrangement on the Accuracy of Current Transformers with Through-Going Primary Cable
April 14, 2023
Abstract
The current transformers with split-core are used for installation in places where it is impossible to install classic current transformers. Moreover, this design allows for any measurement location change, and even switching one current transformer into several different shapes of bars or cables. Power network operators, striving for more accurate current measurements, require producers to provide current transformers with a special accuracy class 0.2S. Therefore, manufacturers and designers try to meet the market requirements and, similarly to non-demountable current transformers, i.e., with a toroidal core, design current transformers with split-core class 0.2S. To meet the high metrological requirements, 3D analyses of electromagnetic fields were performed, taking into account physical phenomena and not approximate analytical models. Two types of cores and four different arrangements of the secondary windings of the measuring current transformers were considered. The magnetic field distributions, current error, and phase displacement diagrams of all current transformer models were analyzed, and the model of the transformer structure with the best accuracy was selected. Computations were conducted based on the finite element numerical method, and the results were compared with the real model tests.
The current transformers with split-core are used for installation in places where it is impossible to install classic current transformers. Moreover, this design allows for any measurement location change, and even switching one current transformer into several different shapes of bars or cables. Power network operators, striving for more accurate current measurements, require producers to provide current transformers with a special accuracy class 0.2S. Therefore, manufacturers and designers try to meet the market requirements and, similarly to non-demountable current transformers, i.e., with a toroidal core, design current transformers with split-core class 0.2S. To meet the high metrological requirements, 3D analyses of electromagnetic fields were performed, taking into account physical phenomena and not approximate analytical models. Two types of cores and four different arrangements of the secondary windings of the measuring current transformers were considered. The magnetic field distributions, current error, and phase displacement diagrams of all current transformer models were analyzed, and the model of the transformer structure with the best accuracy was selected. Computations were conducted based on the finite element numerical method, and the results were compared with the real model tests.
Record ID
Keywords
current transformers accuracy, finite element method, split-core
Subject
Suggested Citation
Lesniewska E. Influence of the Selection of the Core Shape and Winding Arrangement on the Accuracy of Current Transformers with Through-Going Primary Cable. (2023). LAPSE:2023.30587
Author Affiliations
Lesniewska E: Institute of Mechatronics and Information Systems, Lodz University of Technology, 90-924 Lodz, Poland [ORCID]
Journal Name
Energies
Volume
14
Issue
7
First Page
1932
Year
2021
Publication Date
2021-03-31
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14071932, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.30587
This Record
External Link

https://doi.org/10.3390/en14071932
Publisher Version
Download
Meta
Record Statistics
Record Views
250
Version History
[v1] (Original Submission)
Apr 14, 2023
Verified by curator on
Apr 14, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.30587
Record Owner
Auto Uploader for LAPSE
Links to Related Works