Three connection methods for the combined heating systems of a closed-type heat-source tower heat pump (CHTHP) and solar collector (SC) were proposed in this paper: the heat-source tower (HST) and solar collector were connected in series (HST+SC), and the solar collector and heat pump (HP) condenser were connected in series (SC+HP) and in parallel (SC//HP). The calculation module of the closed heat-source tower was built using programming software based on C++ language, and three corresponding calculation models of the combined heating systems were established in the TRNSYS. Under the climatic conditions of the cold season in Changsha, the combined heating performance of the three systems was simulated and analyzed. The results indicate that the simulation results of the established models are in good agreement with the test results, and the simulation results can be used for the research of the system’s combined heating performance. When the outdoor air temperature and solar radiation intensity are low, the HST+SC system has the best heating performance; however, when the solar radiation intensity and ambient temperature are high, the heating performance of the SC//HP system is the best. When the solar radiation intensity and outdoor air temperature are between the previous two working conditions, the SC+HP system is the best performer for heating among the three systems. On the basis of the collector area and heat pump power designed in this study, the best operating condition interval diagrams of the three combined heating systems are established.
Keywords
combined heating, energy saving technology, heat pump, solar energy
Suggested Citation
Shen X, Li N, A Y. Simulation Research on the Heating Performance of the Combined System of Solar Energy and Heat-Source Tower Heat Pump in a Hot Summer and Cold Winter Area. (2023). LAPSE:2023.30471
Author Affiliations
Shen X: College of Civil Engineering, Hunan University, Changsha 410082, China
Li N: College of Civil Engineering, Hunan University, Changsha 410082, China
A Y: College of Civil Engineering, Hunan University, Changsha 410082, China
Journal Name
Energies
Volume
14
Issue
7
First Page
1816
Year
2021
Publication Date
2021-03-24
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14071816, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.30471
This Record
External Link

https://doi.org/10.3390/en14071816
Publisher Version
Download
Files
Apr 14, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
179
Version History
[v1] (Original Submission)
Apr 14, 2023
 
Verified by curator on
Apr 14, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.30471
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version