This paper refers to the issue that mainly appears in distribution grids, where renewable energy sources (RES) are widely installed. In such grids, one of the main problems is the coordination of energy production time with demand time, especially if photovoltaic energy sources are present. To face this problem, battery energy storage units (ESU) can be installed. In recent years, more and more attention has been paid to optimizing the use of ESU. This paper contains a simple description of available solutions for the application of ESU as well as an original proposal for selecting the optimal location and control of ESU. The ESU selection method is based on the use of a genetic algorithm and the ESU control method utilizes the fuzzy logic. The combination of the aforementioned methods/algorithms of ESU application is named an integrated algorithm. The performance of the proposed algorithm was validated by multivariate computer simulations with the use of the real low-voltage grid model. The DIgSILENT PowerFactory environment was employed to develop the simulation model of the integrated algorithm. The proposal was utilized to improve the voltage level in the distribution grid and to install the optimal number of ESU. Based on daily load variations for selected load profiles, it was shown that after the ESU application the voltage deviations in the analyzed network were significantly limited. Moreover, the analysis proves that both the location of ESU in the grid and the control of their active and reactive power are important from the point of view of reducing overall costs.
Keywords
energy storage units, fuzzy logic, Genetic Algorithm, low-voltage grid analysis
Suggested Citation
Szultka A, Szultka S, Czapp S, Lubosny Z, Malkowski R. Integrated Algorithm for Selecting the Location and Control of Energy Storage Units to Improve the Voltage Level in Distribution Grids. (2023). LAPSE:2023.28647
Author Affiliations
Szultka A: Energa-Operator SA, Marynarki Polskiej 130, PL-80-557 Gdańsk, Poland
Szultka S: Faculty of Electrical and Control Engineering, Gdańsk University of Technology, Narutowicza 11/12, PL-80-233 Gdańsk, Poland
Czapp S: Faculty of Electrical and Control Engineering, Gdańsk University of Technology, Narutowicza 11/12, PL-80-233 Gdańsk, Poland [ORCID]
Lubosny Z: Faculty of Electrical and Control Engineering, Gdańsk University of Technology, Narutowicza 11/12, PL-80-233 Gdańsk, Poland
Malkowski R: Faculty of Electrical and Control Engineering, Gdańsk University of Technology, Narutowicza 11/12, PL-80-233 Gdańsk, Poland [ORCID]
Journal Name
Energies
Volume
13
Issue
24
Article Number
E6720
Year
2020
Publication Date
2020-12-19
Published Version
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13246720, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.28647
This Record
External Link

doi:10.3390/en13246720
Publisher Version
Download
Files
[Download 1v1.pdf] (8.8 MB)
Apr 12, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
83
Version History
[v1] (Original Submission)
Apr 12, 2023
 
Verified by curator on
Apr 12, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.28647
 
Original Submitter
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version