Harmonic Overvoltage Analysis of Electric Railways in a Wide Frequency Range Based on Relative Frequency Relationships of the Vehicle−Grid Coupling System
April 12, 2023
Abstract
Harmonic overvoltage in electric railway traction networks can pose a serious threat to the safe and stable operation of the traction power supply system (TPSS). Existing studies aim at improving the control damping of grid-connected converters, neglecting the impedance frequency characteristics (IFCs) of the actual TPSS. The applicable frequency range of these studies is relatively low, usually no more than half of the switching frequency, and there is a large gap with the actual traction network harmonic overvoltage frequency range of 750 Hz−3750 Hz. In this paper, first, the IFCs of the actual TPSS in the wide frequency range of 150 Hz−5000 Hz are obtained through field tests, and the resonant frequency distribution characteristics of TPSS are analyzed. After that, the aliasing effect of the sampling process and the sideband effect of the modulation process of the digital control of the grid-connected converter are considered. Based on the relative relationships among the inherent resonant frequency of the TPSS, sampling frequency and switching frequency, an impedance matching analysis method is proposed for the wide frequency range of the vehicle−grid coupling system. By this method, the sampling frequency and switching frequency can be decoupled, and the harmonic overvoltage of traction network in the frequency range of two times switching frequency and above can be directly estimated. Finally, the method proposed in this paper is validated by the comparative simulation analysis of seven different cases.
Harmonic overvoltage in electric railway traction networks can pose a serious threat to the safe and stable operation of the traction power supply system (TPSS). Existing studies aim at improving the control damping of grid-connected converters, neglecting the impedance frequency characteristics (IFCs) of the actual TPSS. The applicable frequency range of these studies is relatively low, usually no more than half of the switching frequency, and there is a large gap with the actual traction network harmonic overvoltage frequency range of 750 Hz−3750 Hz. In this paper, first, the IFCs of the actual TPSS in the wide frequency range of 150 Hz−5000 Hz are obtained through field tests, and the resonant frequency distribution characteristics of TPSS are analyzed. After that, the aliasing effect of the sampling process and the sideband effect of the modulation process of the digital control of the grid-connected converter are considered. Based on the relative relationships among the inherent resonant frequency of the TPSS, sampling frequency and switching frequency, an impedance matching analysis method is proposed for the wide frequency range of the vehicle−grid coupling system. By this method, the sampling frequency and switching frequency can be decoupled, and the harmonic overvoltage of traction network in the frequency range of two times switching frequency and above can be directly estimated. Finally, the method proposed in this paper is validated by the comparative simulation analysis of seven different cases.
Record ID
Keywords
electric railway, harmonic overvoltage, harmonic resonance, resonant frequency, stability analysis, traction power supply system
Subject
Suggested Citation
Liu Q, Sun B, Yang Q, Wu M, He T. Harmonic Overvoltage Analysis of Electric Railways in a Wide Frequency Range Based on Relative Frequency Relationships of the Vehicle−Grid Coupling System. (2023). LAPSE:2023.28598
Author Affiliations
Liu Q: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
Sun B: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
Yang Q: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
Wu M: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
He T: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China [ORCID]
Sun B: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
Yang Q: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
Wu M: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China
He T: School of Electrical Engineering, Beijing Jiaotong University, Beijing 100044, China [ORCID]
Journal Name
Energies
Volume
13
Issue
24
Article Number
E6672
Year
2020
Publication Date
2020-12-17
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13246672, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.28598
This Record
External Link

https://doi.org/10.3390/en13246672
Publisher Version
Download
Meta
Record Statistics
Record Views
174
Version History
[v1] (Original Submission)
Apr 12, 2023
Verified by curator on
Apr 12, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.28598
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.35 seconds)