LAPSE:2023.28473v1
Published Article

LAPSE:2023.28473v1
Controlling the Thermal Power of a Wall Heating Panel with Heat Pipes by Changing the Mass Flowrate and Temperature of Supplying Water—Experimental Investigations
April 11, 2023
Abstract
Renewable energy sources for the purpose of heating buildings cooperate perfectly with so-called low-temperature heating systems. Water loop surface heating systems had been thoroughly tested. In contrast, thermal performance of wall panels with heat pipes have not been fully recognized, yet. The determination of the thermal power as well as the control of panels thermal performance cannot be performed with the methods developed for water loop systems. In this paper, the novel heating panels with heat pipes were tested to analyze the possibility of controlling their performance by changing the mass flowrate of heating water and its temperature. Specific heating power of the investigated panels varies from 16.9 W/m2 to 93.8 W/m2 when supplying a water temperature ranging from 35 °C to 65 °C and mass flowrate from 10 g/s to 47.5 g/s. Investigations revealed that the thermal performance of the panels is more sensitive to the changes of temperature than to the changes of mass flowrate of supplying water, and thus, should be controlled by changing the supply water temperature at low mass flowrates to obtain a low energy usage of pumps (diminished pressure losses) and good quality of controlling.
Renewable energy sources for the purpose of heating buildings cooperate perfectly with so-called low-temperature heating systems. Water loop surface heating systems had been thoroughly tested. In contrast, thermal performance of wall panels with heat pipes have not been fully recognized, yet. The determination of the thermal power as well as the control of panels thermal performance cannot be performed with the methods developed for water loop systems. In this paper, the novel heating panels with heat pipes were tested to analyze the possibility of controlling their performance by changing the mass flowrate of heating water and its temperature. Specific heating power of the investigated panels varies from 16.9 W/m2 to 93.8 W/m2 when supplying a water temperature ranging from 35 °C to 65 °C and mass flowrate from 10 g/s to 47.5 g/s. Investigations revealed that the thermal performance of the panels is more sensitive to the changes of temperature than to the changes of mass flowrate of supplying water, and thus, should be controlled by changing the supply water temperature at low mass flowrates to obtain a low energy usage of pumps (diminished pressure losses) and good quality of controlling.
Record ID
Keywords
heat pipes, low energy buildings, low-temperature heating, nearly zero energy building (nZEB), radiant heating, surface heating, thermal characteristics, thermal performance control, wall-type heating system
Subject
Suggested Citation
Amanowicz Ł. Controlling the Thermal Power of a Wall Heating Panel with Heat Pipes by Changing the Mass Flowrate and Temperature of Supplying Water—Experimental Investigations. (2023). LAPSE:2023.28473v1
Author Affiliations
Amanowicz Ł: Institute of Environmental Engineering and Building Services, Poznan University of Technology, 60-965 Poznan, Poland [ORCID]
Journal Name
Energies
Volume
13
Issue
24
Article Number
E6547
Year
2020
Publication Date
2020-12-11
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13246547, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.28473v1
This Record
External Link

https://doi.org/10.3390/en13246547
Publisher Version
Download
Meta
Record Statistics
Record Views
376
Version History
[v1] (Original Submission)
Apr 11, 2023
Verified by curator on
Apr 11, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.28473v1
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.08 seconds)
[0.09 s]
