LAPSE:2023.27001
Published Article

LAPSE:2023.27001
A Tandem Axial-Piston Unit Based Strategy for the Reduction of Noise Sources in Hydraulic Systems
April 3, 2023
Abstract
This article presents a novel passive fluid borne noise source reduction strategy, based on tandem axial-piston unit indexing with the usage of symmetric lines. The strategy consists of setting the phase between the two synchronous units to accomplish destructive interference in targeted unit harmonics. A strategy capable of achieving destructive interference in all odd harmonics is investigated first analytically and then confirmed by a simulation study. Experiments on the proposed strategy confirmed its effectiveness at the first and third pump fundamental harmonics, and pressure ripple reduction was accomplished. The fluid borne noise source reduction in the first and third harmonic is verified to be propagated to pipe vibration and sound power. Regarding the first harmonic, pressure ripple was reduced by up to 18 dB; while for third harmonic, pressure ripple was reduced by up to 11 dB. In the experiment, however, noise cancellation is not achieved for the higher odd harmonics, as is instead found in the simulation. Conversely, transfer functions form pressure ripple to pipe wall acceleration are obtained experimentally, and a critical vibration band from 2000 Hz to 3000 Hz is identified as being crucial for effective overall sound power reduction.
This article presents a novel passive fluid borne noise source reduction strategy, based on tandem axial-piston unit indexing with the usage of symmetric lines. The strategy consists of setting the phase between the two synchronous units to accomplish destructive interference in targeted unit harmonics. A strategy capable of achieving destructive interference in all odd harmonics is investigated first analytically and then confirmed by a simulation study. Experiments on the proposed strategy confirmed its effectiveness at the first and third pump fundamental harmonics, and pressure ripple reduction was accomplished. The fluid borne noise source reduction in the first and third harmonic is verified to be propagated to pipe vibration and sound power. Regarding the first harmonic, pressure ripple was reduced by up to 18 dB; while for third harmonic, pressure ripple was reduced by up to 11 dB. In the experiment, however, noise cancellation is not achieved for the higher odd harmonics, as is instead found in the simulation. Conversely, transfer functions form pressure ripple to pipe wall acceleration are obtained experimentally, and a critical vibration band from 2000 Hz to 3000 Hz is identified as being crucial for effective overall sound power reduction.
Record ID
Keywords
axial-piston machine, destructive interference, flow ripple, fluid borne noise, passive vibration reduction
Subject
Suggested Citation
Danes L, Vacca A. A Tandem Axial-Piston Unit Based Strategy for the Reduction of Noise Sources in Hydraulic Systems. (2023). LAPSE:2023.27001
Author Affiliations
Danes L: Maha Fluid Power Research Center, Purdue University, Lafayette, IN 47905, USA
Vacca A: Maha Fluid Power Research Center, Purdue University, Lafayette, IN 47905, USA [ORCID]
Vacca A: Maha Fluid Power Research Center, Purdue University, Lafayette, IN 47905, USA [ORCID]
Journal Name
Energies
Volume
13
Issue
20
Article Number
E5377
Year
2020
Publication Date
2020-10-15
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13205377, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.27001
This Record
External Link

https://doi.org/10.3390/en13205377
Publisher Version
Download
Meta
Record Statistics
Record Views
167
Version History
[v1] (Original Submission)
Apr 3, 2023
Verified by curator on
Apr 3, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.27001
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.35 seconds) 0.04 + 0.04 + 0.14 + 0.05 + 0 + 0.02 + 0.01 + 0 + 0.01 + 0.02 + 0 + 0
