Evaluating the Energy Efficiency and Environmental Impact of COVID-19 Vaccines Coolers through New Optimization Indexes: Comparison between Refrigeration Systems Using HFC or Natural Refrigerants
February 21, 2023
Abstract
COVID-19 vaccines are used worldwide to promote immunity and, in that sense, vaccination is a step forward toward ending the pandemic. Nevertheless, current vaccines must be ultra-cold or cold-stored. Vaccine coolers’ energy demand and greenhouse gas emissions lead to a significant environmental impact. This article predicts the environmental and energy impacts of some COVID-19 vaccines: Moderna, Janssen, CoronaVac, Pfizer, AstraZeneca−Oxford−Covishield, and Sputnik V, in terms of carbon dioxide emissions using a new approach for the TEWI (Total Equivalent Warming Impact) methodology, with several options of refrigerants from halogenated to natural fluids such as propane, which is natural gas with low GWP (global warming potential). Through the application of new optimization indexes, it is concluded that the evaporation temperature of the refrigerant gas has a great influence on the sizing of the coolers. For example, for the same number of vaccines, the thermal load of Pfizer is more than double that of AstraZeneca−Covishield, CoronaVac, or Janssen, while the direct environmental impact is seven times greater. Another relevant factor is the choice of refrigerant. For example, the greenhouse effect varies greatly for the same brand of vaccine. The Moderna vaccine’s global warming potential (GWP) is 776 times higher using R-449A gas than using R-290 (propane gas). In Brazil, the refrigerators used to store the Pfizer vaccine have a total TEWI almost two times higher than the total TEWI of refrigerators using propane to store the Janssen vaccine. At this time of the pandemic, these optimization indexes can be used to support important decisions regarding the future selection of vaccine brands considering the energy consumption and environmental impact required for their storage.
COVID-19 vaccines are used worldwide to promote immunity and, in that sense, vaccination is a step forward toward ending the pandemic. Nevertheless, current vaccines must be ultra-cold or cold-stored. Vaccine coolers’ energy demand and greenhouse gas emissions lead to a significant environmental impact. This article predicts the environmental and energy impacts of some COVID-19 vaccines: Moderna, Janssen, CoronaVac, Pfizer, AstraZeneca−Oxford−Covishield, and Sputnik V, in terms of carbon dioxide emissions using a new approach for the TEWI (Total Equivalent Warming Impact) methodology, with several options of refrigerants from halogenated to natural fluids such as propane, which is natural gas with low GWP (global warming potential). Through the application of new optimization indexes, it is concluded that the evaporation temperature of the refrigerant gas has a great influence on the sizing of the coolers. For example, for the same number of vaccines, the thermal load of Pfizer is more than double that of AstraZeneca−Covishield, CoronaVac, or Janssen, while the direct environmental impact is seven times greater. Another relevant factor is the choice of refrigerant. For example, the greenhouse effect varies greatly for the same brand of vaccine. The Moderna vaccine’s global warming potential (GWP) is 776 times higher using R-449A gas than using R-290 (propane gas). In Brazil, the refrigerators used to store the Pfizer vaccine have a total TEWI almost two times higher than the total TEWI of refrigerators using propane to store the Janssen vaccine. At this time of the pandemic, these optimization indexes can be used to support important decisions regarding the future selection of vaccine brands considering the energy consumption and environmental impact required for their storage.
Record ID
Keywords
COVID-19, energy consumption, environmental impact, EUED, HFC, propane, SARS CoV-2, TEWI, vaccines
Subject
Suggested Citation
Santos AF, Gaspar PD, de Souza HJL. Evaluating the Energy Efficiency and Environmental Impact of COVID-19 Vaccines Coolers through New Optimization Indexes: Comparison between Refrigeration Systems Using HFC or Natural Refrigerants. (2023). LAPSE:2023.2664v1
Author Affiliations
Santos AF: Department of Electromechanical Engineering, University of Beira Interior, 6201-001 Covilhã, Portugal; FAPRO—Professional College, Curitiba 80230-040, Brazil
Gaspar PD: Department of Electromechanical Engineering, University of Beira Interior, 6201-001 Covilhã, Portugal; C-MAST—Centre for Mechanical and Aerospace Science and Technologies, 6201-001 Covilhã, Portugal [ORCID]
de Souza HJL: FAPRO—Professional College, Curitiba 80230-040, Brazil
Gaspar PD: Department of Electromechanical Engineering, University of Beira Interior, 6201-001 Covilhã, Portugal; C-MAST—Centre for Mechanical and Aerospace Science and Technologies, 6201-001 Covilhã, Portugal [ORCID]
de Souza HJL: FAPRO—Professional College, Curitiba 80230-040, Brazil
Journal Name
Processes
Volume
10
Issue
4
First Page
790
Year
2022
Publication Date
2022-04-17
ISSN
2227-9717
Version Comments
Original Submission
Other Meta
PII: pr10040790, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.2664v1
This Record
External Link

https://doi.org/10.3390/pr10040790
Publisher Version
Download
Meta
Record Statistics
Record Views
347
Version History
[v1] (Original Submission)
Feb 21, 2023
Verified by curator on
Feb 21, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.2664v1
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.07 seconds)
[0.08 s]