Abstract
Among the main causes of outdoor insulation failures is their poor specifications in terms of leakage distances. This happens when the selected criteria are unable to cope with all the stresses imposed by the changes in environmental pollutions. Therefore, it is important for utilities to fully understand the actual pollution characteristics of the service environment in which the insulators are operating. In this paper, the pollution severity and performance of some 13.2 kV ceramic insulators, sampled in different areas of a Canadian aluminum factory, are assessed. The investigations were performed taking into account the influence of air humidity. Various characteristics were investigated to assess the pollution levels of the insulators, such as equivalent salt deposit density (ESDD) and non-soluble deposit density (NSDD), surface resistance, and leakage current characteristics (density, 3rd harmonic amplitude, and phase). It was witnessed that the insulators, collected around the factory, were much more polluted in comparison to the initial expectation. The pollution level should not be considered static due to the environmental parameters’ dynamics. Lessons to learn: the reliability of an electrical grid is dependent on components whose own reliability is strongly affected by external factors, of which there is often a poor awareness. If care is not taken to re-evaluate the post-installation pollution levels of the insulators, the light may simply turn out!
Keywords
equivalent salt deposit density (ESDD), humidity, insulator, leakage current, non-soluble deposit density (NSDD), pollution, post-installation study
Suggested Citation
Fofana I, N’cho JS, Betie A, Hounton E, Meghnefi F, Yapi KML. Lessons to Learn from Post-Installation Pollution Levels Assessment of Some Distribution Insulators. (2023). LAPSE:2023.25701v1
Author Affiliations
Fofana I: Research Chair on the Aging of Power Network Infrastructure (ViAHT), Université du Québec à Chicoutimi, 555 Boulevard de l’Université, Chicoutimi, QC G7H 2B1, Canada [ORCID]
N’cho JS: Département Génie Électrique et Électronique, Institut National Polytechnique Houphouët Boigny (INP-HB), Yamoussoukro BP 1093, Cote D’Ivoire [ORCID]
Betie A: Département Génie Électrique et Électronique, Institut National Polytechnique Houphouët Boigny (INP-HB), Yamoussoukro BP 1093, Cote D’Ivoire
Hounton E: Research Chair on the Aging of Power Network Infrastructure (ViAHT), Université du Québec à Chicoutimi, 555 Boulevard de l’Université, Chicoutimi, QC G7H 2B1, Canada
Meghnefi F: Research Chair on the Aging of Power Network Infrastructure (ViAHT), Université du Québec à Chicoutimi, 555 Boulevard de l’Université, Chicoutimi, QC G7H 2B1, Canada
Yapi KML: Research Chair on the Aging of Power Network Infrastructure (ViAHT), Université du Québec à Chicoutimi, 555 Boulevard de l’Université, Chicoutimi, QC G7H 2B1, Canada
Journal Name
Energies
Volume
13
Issue
16
Article Number
E4064
Year
2020
Publication Date
2020-08-06
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13164064, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.25701v1
This Record
External Link

https://doi.org/10.3390/en13164064
Publisher Version
Download
Files
Mar 29, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
163
Version History
[v1] (Original Submission)
Mar 29, 2023
 
Verified by curator on
Mar 29, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.25701v1
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version