LAPSE:2023.24212
Published Article

LAPSE:2023.24212
Important Factors for Consideration during the Specification of SF6 Circuit Breakers for High Voltage Generators
March 27, 2023
Abstract
This paper describes and analyzes the phenomena that occur in the case of a current interruption due to faults in the high voltage circuit breaker. That happens during connection of a generator to the network without meeting the synchronization conditions. This paper also describes and analyzes the important factors that have to be considered during the specification of SF6 circuit breakers for high voltage generators. A high direct current component in the fault current poses a major problem during such interruptions. To investigate this problem and propose possible solutions, simulations were performed on a power network model completed with the network’s data, using software such as EMTP-ATP, PSS-E and MATLAB. Various modes of operation were simulated, which are important for analyzing the strain on circuit breakers near the generator. Based on the performed simulations, it can be concluded that circuit breakers with rapid reactions in interrupting the fault current in an energy system are not always a favorable solution due to the high value of the direct current component in the fault current, which prevents the current from passing through zero within a short time.
This paper describes and analyzes the phenomena that occur in the case of a current interruption due to faults in the high voltage circuit breaker. That happens during connection of a generator to the network without meeting the synchronization conditions. This paper also describes and analyzes the important factors that have to be considered during the specification of SF6 circuit breakers for high voltage generators. A high direct current component in the fault current poses a major problem during such interruptions. To investigate this problem and propose possible solutions, simulations were performed on a power network model completed with the network’s data, using software such as EMTP-ATP, PSS-E and MATLAB. Various modes of operation were simulated, which are important for analyzing the strain on circuit breakers near the generator. Based on the performed simulations, it can be concluded that circuit breakers with rapid reactions in interrupting the fault current in an energy system are not always a favorable solution due to the high value of the direct current component in the fault current, which prevents the current from passing through zero within a short time.
Record ID
Keywords
alternating current component, asynchronous connection, circuit breaker, direct current component, energy system, generator
Subject
Suggested Citation
Alidemaj A, Nika Q. Important Factors for Consideration during the Specification of SF6 Circuit Breakers for High Voltage Generators. (2023). LAPSE:2023.24212
Author Affiliations
Alidemaj A: Faculty of Electrical Engineering, University of Montenegro, 81000 Podgorica, Montenegro
Nika Q: GE Renewable Energy, General Electric International INC, 10000 Pristina, Kosovo [ORCID]
Nika Q: GE Renewable Energy, General Electric International INC, 10000 Pristina, Kosovo [ORCID]
Journal Name
Energies
Volume
13
Issue
14
Article Number
E3608
Year
2020
Publication Date
2020-07-13
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13143608, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.24212
This Record
External Link

https://doi.org/10.3390/en13143608
Publisher Version
Download
Meta
Record Statistics
Record Views
172
Version History
[v1] (Original Submission)
Mar 27, 2023
Verified by curator on
Mar 27, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.24212
Record Owner
Auto Uploader for LAPSE
Links to Related Works
