Control Strategy for Helicopter Thermal Management System Based on Liquid Cooling and Vapor Compression Refrigeration
March 24, 2023
Abstract
With the continuous application of high-power electronic equipment in aircraft, highly efficient heat transfer technology has been emphasized for airborne applications. In this paper, a thermal management system based on an antifreeze liquid cooling loop and a vapor compression refrigeration loop is presented for high-power airborne equipment in a helicopter. The simulation models of the thermal management system are built in order to study its control strategy for the changing flight conditions. The antifreeze-refrigerant evaporator and air-refrigerant condenser are specially validated with the experimental data. A dual feedforward proportion integration differentiation and expert control algorithm are adopted in the inlet temperature of the cold plate and sub-cooling control of the refrigerant by regulating the compressor speed and the fan speed, respectively. A preheating strategy for antifreeze is set up to decrease its flow resistance in cold day conditions. The control strategy for the thermal management system is finally built based on the above control methods. In this paper, two extreme conditions are discussed, including cold and hot days. Both the simulation results show that the superheated, sub-cooling and antifreeze inlet temperature of the cold plate can be controlled at 3 to8 °C, −10 to −3 °C and 18 to22 °C, respectively. Under the same changing flight envelope, the coefficient of performance of the vapor compression refrigeration loop is relatively stable on the cold day, which is about 6, while it has a range of 2.58−4.9 on the hot day.
With the continuous application of high-power electronic equipment in aircraft, highly efficient heat transfer technology has been emphasized for airborne applications. In this paper, a thermal management system based on an antifreeze liquid cooling loop and a vapor compression refrigeration loop is presented for high-power airborne equipment in a helicopter. The simulation models of the thermal management system are built in order to study its control strategy for the changing flight conditions. The antifreeze-refrigerant evaporator and air-refrigerant condenser are specially validated with the experimental data. A dual feedforward proportion integration differentiation and expert control algorithm are adopted in the inlet temperature of the cold plate and sub-cooling control of the refrigerant by regulating the compressor speed and the fan speed, respectively. A preheating strategy for antifreeze is set up to decrease its flow resistance in cold day conditions. The control strategy for the thermal management system is finally built based on the above control methods. In this paper, two extreme conditions are discussed, including cold and hot days. Both the simulation results show that the superheated, sub-cooling and antifreeze inlet temperature of the cold plate can be controlled at 3 to8 °C, −10 to −3 °C and 18 to22 °C, respectively. Under the same changing flight envelope, the coefficient of performance of the vapor compression refrigeration loop is relatively stable on the cold day, which is about 6, while it has a range of 2.58−4.9 on the hot day.
Record ID
Keywords
antifreeze liquid cooling, control strategy, high-power, thermal management system, vapor compression refrigeration
Subject
Suggested Citation
Zhao M, Pang L, Liu M, Yu S, Mao X. Control Strategy for Helicopter Thermal Management System Based on Liquid Cooling and Vapor Compression Refrigeration. (2023). LAPSE:2023.22961
Author Affiliations
Zhao M: School of Aviation Science and Engineering, Beijing University of Aeronautics and Astronautics (BUAA), Beijing 100191, China
Pang L: School of Aviation Science and Engineering, Beijing University of Aeronautics and Astronautics (BUAA), Beijing 100191, China
Liu M: School of Aviation Science and Engineering, Beijing University of Aeronautics and Astronautics (BUAA), Beijing 100191, China
Yu S: AVIC Xinxiang Aviation Industry (Group) CO, LTD, Xinxiang 453049, China
Mao X: School of Aero-engine, Shenyang Aerospace University, Shenyang 110136, China
Pang L: School of Aviation Science and Engineering, Beijing University of Aeronautics and Astronautics (BUAA), Beijing 100191, China
Liu M: School of Aviation Science and Engineering, Beijing University of Aeronautics and Astronautics (BUAA), Beijing 100191, China
Yu S: AVIC Xinxiang Aviation Industry (Group) CO, LTD, Xinxiang 453049, China
Mao X: School of Aero-engine, Shenyang Aerospace University, Shenyang 110136, China
Journal Name
Energies
Volume
13
Issue
9
Article Number
E2177
Year
2020
Publication Date
2020-05-01
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13092177, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.22961
This Record
External Link

https://doi.org/10.3390/en13092177
Publisher Version
Download
Meta
Record Statistics
Record Views
371
Version History
[v1] (Original Submission)
Mar 24, 2023
Verified by curator on
Mar 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.22961
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.09 seconds)
[0.09 s]