LAPSE:2023.22946
Published Article

LAPSE:2023.22946
Energy-Saving Potential of Extending Temperature Set-Points in a VRF Air-Conditioned Building
March 24, 2023
Abstract
Building energy savings and occupant thermal comfort are the main issues in building technology. As such, the development of energy-efficient heating, ventilation, and air-conditioning (HVAC) systems and the control strategies of HVAC systems are emerging as important topics in the HVAC industry. Variable refrigerant flow (VRF) systems have efficient energy performance, so the use of VRF systems in buildings is increasing. However, most studies on VRF systems focus on improving mechanical efficiency, with few studies on energy-efficient control while satisfying the thermal comfort of occupants. The goal is to estimate the energy-saving potential of adjusting the temperature set-points and dead-band (range) in VRF air-conditioned building. To do so, we analyzed the influence of control strategies of a VRF system on human thermal comfort and energy consumption using a simulation method. The results showed that energy consumption can be reduced by 25.4% for predicted mean vote (PMV)-based control and 27.0% for the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) comfort range control compared with the typical set-point temperature control of a VRF system. The indoor thermal environments of the analyzed control strategies are controlled in the thermal comfort range, which is based on a PMV at ±0.5. Compared with the typical set-point control, PMV and ASHRAE comfort range-based control reduced the operation time of the compressor in the VRF system.
Building energy savings and occupant thermal comfort are the main issues in building technology. As such, the development of energy-efficient heating, ventilation, and air-conditioning (HVAC) systems and the control strategies of HVAC systems are emerging as important topics in the HVAC industry. Variable refrigerant flow (VRF) systems have efficient energy performance, so the use of VRF systems in buildings is increasing. However, most studies on VRF systems focus on improving mechanical efficiency, with few studies on energy-efficient control while satisfying the thermal comfort of occupants. The goal is to estimate the energy-saving potential of adjusting the temperature set-points and dead-band (range) in VRF air-conditioned building. To do so, we analyzed the influence of control strategies of a VRF system on human thermal comfort and energy consumption using a simulation method. The results showed that energy consumption can be reduced by 25.4% for predicted mean vote (PMV)-based control and 27.0% for the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) comfort range control compared with the typical set-point temperature control of a VRF system. The indoor thermal environments of the analyzed control strategies are controlled in the thermal comfort range, which is based on a PMV at ±0.5. Compared with the typical set-point control, PMV and ASHRAE comfort range-based control reduced the operation time of the compressor in the VRF system.
Record ID
Keywords
ASHRAE comfort range, energy savings, extending temperature set-point, PMV comfort range, variable refrigerant flow (VRF)
Subject
Suggested Citation
Kim J, Song D, Kim S, Park S, Choi Y, Lim H. Energy-Saving Potential of Extending Temperature Set-Points in a VRF Air-Conditioned Building. (2023). LAPSE:2023.22946
Author Affiliations
Kim J: Center for Built Environment, Sungkyunkwan University, Suwon 16419, Korea [ORCID]
Song D: School of Civil, Architectural Engineering and Landscape Architecture, Sungkyunkwan University, Suwon 16419, Korea
Kim S: Graduate School, Sungkyunkwan University, Suwon 16419, Korea
Park S: Graduate School, Sungkyunkwan University, Suwon 16419, Korea
Choi Y: Department of Architectural Engineering, Kyonggi University, Suwon 16227, Korea [ORCID]
Lim H: Ecotope, Inc., 1917 1st Ave., Seattle, WA 98101, USA
Song D: School of Civil, Architectural Engineering and Landscape Architecture, Sungkyunkwan University, Suwon 16419, Korea
Kim S: Graduate School, Sungkyunkwan University, Suwon 16419, Korea
Park S: Graduate School, Sungkyunkwan University, Suwon 16419, Korea
Choi Y: Department of Architectural Engineering, Kyonggi University, Suwon 16227, Korea [ORCID]
Lim H: Ecotope, Inc., 1917 1st Ave., Seattle, WA 98101, USA
Journal Name
Energies
Volume
13
Issue
9
Article Number
E2160
Year
2020
Publication Date
2020-05-01
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13092160, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.22946
This Record
External Link

https://doi.org/10.3390/en13092160
Publisher Version
Download
Meta
Record Statistics
Record Views
371
Version History
[v1] (Original Submission)
Mar 24, 2023
Verified by curator on
Mar 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.22946
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.09 seconds)
[0.09 s]
