LAPSE:2023.22849
Published Article

LAPSE:2023.22849
Uplift Bearing Capacity of Cone-Cylinder Foundation for Transmission Line in Frozen Soil Regions, Using Reduced-Scale Model Tests and Numerical Simulations
March 24, 2023
Abstract
In order to analyze the uplift bearing capacity of cone-cylinder foundation for transmission line in frozen soil regions, a series of reduced-scale modeling tests and numerical simulations are carried out. First, three reduced-scale cone-cylinder foundations with the same sizes, that are five times smaller than the prototype, are made and then loaded under uplift load at −5 °C, −10 °C, and −15 °C, respectively. On this basis, the foundations of nine sizes are modeled and loaded by numerical simulation. The impact of three dimension factors, including the ratio of depth to bottom width ( λ = h t / D t ), the top diameter of the cone-cylinder (d), and the bottom diameter of the cone-cylinder (D), on the uplift bearing capacity of foundations have been investigated. The results reveal that, for cone-cylinder foundation, the uplift bearing capacity is obviously affected by the freezing temperatures and the foundation sizes. The capacity is negatively correlated with the former. Whereas the order of correlation with the latter is as follows: λ, D, and d based on the comprehensive results of range and variance analysis, but none of them are the significant factors, according to the F-test. Furthermore, three failure mechanisms of frozen soil are distinguished and named T-mode, V-mode, and U-mode, respectively. Based on the above results, the bearing mechanism of cone-cylinder foundation in frozen soil is elaborated in detail.
In order to analyze the uplift bearing capacity of cone-cylinder foundation for transmission line in frozen soil regions, a series of reduced-scale modeling tests and numerical simulations are carried out. First, three reduced-scale cone-cylinder foundations with the same sizes, that are five times smaller than the prototype, are made and then loaded under uplift load at −5 °C, −10 °C, and −15 °C, respectively. On this basis, the foundations of nine sizes are modeled and loaded by numerical simulation. The impact of three dimension factors, including the ratio of depth to bottom width ( λ = h t / D t ), the top diameter of the cone-cylinder (d), and the bottom diameter of the cone-cylinder (D), on the uplift bearing capacity of foundations have been investigated. The results reveal that, for cone-cylinder foundation, the uplift bearing capacity is obviously affected by the freezing temperatures and the foundation sizes. The capacity is negatively correlated with the former. Whereas the order of correlation with the latter is as follows: λ, D, and d based on the comprehensive results of range and variance analysis, but none of them are the significant factors, according to the F-test. Furthermore, three failure mechanisms of frozen soil are distinguished and named T-mode, V-mode, and U-mode, respectively. Based on the above results, the bearing mechanism of cone-cylinder foundation in frozen soil is elaborated in detail.
Record ID
Keywords
frozen soil, numerical modeling, power transmission line, reduced-scale modeling test, ultimate uplift load
Subject
Suggested Citation
Han Y, Cheng J, Cui Q, Dong Q, Song W. Uplift Bearing Capacity of Cone-Cylinder Foundation for Transmission Line in Frozen Soil Regions, Using Reduced-Scale Model Tests and Numerical Simulations. (2023). LAPSE:2023.22849
Author Affiliations
Han Y: College of Geoscience and Surveying Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China
Cheng J: College of Geoscience and Surveying Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China [ORCID]
Cui Q: Power Transmission and Transformation Engineering Department, China Electric Power Research Institute, Beijing 102401, China
Dong Q: College of Geoscience and Surveying Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China
Song W: College of Humanity and Law, China University of Mining and Technology (Beijing), Beijing 100083, China
Cheng J: College of Geoscience and Surveying Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China [ORCID]
Cui Q: Power Transmission and Transformation Engineering Department, China Electric Power Research Institute, Beijing 102401, China
Dong Q: College of Geoscience and Surveying Engineering, China University of Mining and Technology (Beijing), Beijing 100083, China
Song W: College of Humanity and Law, China University of Mining and Technology (Beijing), Beijing 100083, China
Journal Name
Energies
Volume
13
Issue
8
Article Number
E2066
Year
2020
Publication Date
2020-04-21
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13082066, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.22849
This Record
External Link

https://doi.org/10.3390/en13082066
Publisher Version
Download
Meta
Record Statistics
Record Views
160
Version History
[v1] (Original Submission)
Mar 24, 2023
Verified by curator on
Mar 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.22849
Record Owner
Auto Uploader for LAPSE
Links to Related Works