Annual Energy Consumption Cut-Off with Cooling System Design Parameter Changes in Large Office Buildings
Ju-wan Ha, Soolyeon Cho, Hwan-yong Kim, Young-hak Song
March 24, 2023
Abstract
A variety of greenhouse gas reduction scenarios have been proposed around the world to ensure sustainable developments and strengthen the global response to the climate change. To cope with this, it is urgently needed to reduce the amount of energy used for the heating, ventilating, air conditioning, and refrigerating (HVAC&R) systems in large buildings. This study discusses the reduction of cooling energy in large office buildings through the minimization of changes in components and equipment, such as heat source equipment and pumps, changes in the layout and operating methods of chilled water circulation pumps, and changes in the temperatures of chilled and condenser water. To do this, this study targeted an entire cooling system consisting of a hydronic system, a chiller, and a cooling tower, and conducted a quantitative analysis of the energy consumption and of the reduction achieved through a change in the pumping system type in the cooling system and a change in the Korean standard design and temperature of chiller and cooling tower via EnergyPlus simulations. The simulation results showed a cooling energy reduction of 103.2 MWh/yr, around 15.7%, where the primary constant-speed system (Case A) was changed to a primary variable-speed pump (Case B) in the configuration with a chilled water circulation pump. To reduce the cooling energy further, annually 142.3 MWh, around 21.7%, Case C in this study changed the outlet temperature of the chiller and temperature difference from 7 °C, 5 K to 9 °C, 9 K. Finally, when applying a change in the condenser water production temperature from 32 to 23.9 °C in accordance with ASHRAE Standard 90.1 for Case D, a cooling energy saving of 182.4 MWh/yr was observed, which is about 27.8%.
Keywords
chilled water, cooling tower control, energy consumption, large office, low-temperature condenser water
Suggested Citation
Ha JW, Cho S, Kim HY, Song YH. Annual Energy Consumption Cut-Off with Cooling System Design Parameter Changes in Large Office Buildings. (2023). LAPSE:2023.22822
Author Affiliations
Ha JW: Department of Architectural Engineering, Graduate School, Gyeongsang National University, Jinju 52828, Korea [ORCID]
Cho S: School of Architecture, College of Design North Carolina State University, Raleigh, NC 27695, USA
Kim HY: Department of Architectural Engineering, ERI, Gyeongsang National University, Jinju 52828, Korea
Song YH: Department of Architectural Engineering, ERI, Gyeongsang National University, Jinju 52828, Korea [ORCID]
Journal Name
Energies
Volume
13
Issue
8
Article Number
E2034
Year
2020
Publication Date
2020-04-19
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13082034, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.22822
This Record
External Link

https://doi.org/10.3390/en13082034
Publisher Version
Download
Files
Mar 24, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
344
Version History
[v1] (Original Submission)
Mar 24, 2023
 
Verified by curator on
Mar 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.22822
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version
(0.08 seconds)

[0.08 s]