LAPSE:2023.22739
Published Article
LAPSE:2023.22739
Energy Monitoring in a Heating and Cooling System in a Building Based on the Example of the Turówka Hotel
Marek Borowski, Piotr Mazur, Sławosz Kleszcz, Klaudia Zwolińska
March 24, 2023
Abstract
The energy consumption of buildings is very important for both economic and environmental reasons. Newly built buildings are characterized by higher insulation and airtightness of the building envelope, and are additionally equipped with technologies that minimize energy consumption in order to meet legal requirements. In existing buildings, the modernization process should be properly planned, taking into account available technologies and implementation possibilities. Hotel buildings are characterized by a large variability of energy demand, both on a daily and a yearly basis. Monitoring systems, therefore, provide the necessary information needed for proper energy management in the building. This article presents an energy analysis of the Turówka hotel located in Wieliczka (southern Poland). The historical hotel facility is being modernized as part of the project to adapt the building to the requirements of a sustainable building. The modernization proposal includes a trigeneration system with a multifunctional reverse regenerator and control module using neural algorithms. The main purpose is to improve the energy efficiency of the building and adapt it to the requirements of low-energy buildings. The implementation of a monitoring system enables energy consumption to be reduced and improves the energy performance of the building, especially through using energy management systems and control modules. The proposed retrofit solution considers the high energy consumption, structure of the energy demand, and limits of retrofit intervention on façades.
Keywords
Energy Efficiency, energy monitoring, heating and cooling system, nearly zero-energy buildings, sustainable buildings, ventilation
Suggested Citation
Borowski M, Mazur P, Kleszcz S, Zwolińska K. Energy Monitoring in a Heating and Cooling System in a Building Based on the Example of the Turówka Hotel. (2023). LAPSE:2023.22739
Author Affiliations
Borowski M: Faculty of Mining and Geoengineering, AGH University of Science and Technology, 30-059 Kraków, Poland [ORCID]
Mazur P: Frapol Sp. z o.o., 30-832 Kraków, Poland
Kleszcz S: Frapol Sp. z o.o., 30-832 Kraków, Poland; Faculty of Energy and Fuels, AGH University of Science and Technology, 30-059 Kraków, Poland
Zwolińska K: Faculty of Mining and Geoengineering, AGH University of Science and Technology, 30-059 Kraków, Poland [ORCID]
Journal Name
Energies
Volume
13
Issue
8
Article Number
E1968
Year
2020
Publication Date
2020-04-16
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13081968, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.22739
This Record
External Link

https://doi.org/10.3390/en13081968
Publisher Version
Download
Files
Mar 24, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
223
Version History
[v1] (Original Submission)
Mar 24, 2023
 
Verified by curator on
Mar 24, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.22739
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version