LAPSE:2023.21409
Published Article
LAPSE:2023.21409
Experimental Validation of a Numerical Model of a Ventilated Façade with Horizontal and Vertical Open Joints
María Nuria Sánchez, Emanuela Giancola, Eduardo Blanco, Silvia Soutullo, María José Suárez
March 22, 2023
Abstract
Commercial and residential building is one of the four major final energy consumption and end-use sectors. In this sector, cooling loads represent an important part of the energy consumption, and therefore, they must be minimized, improving the energy efficiency of buildings. Ventilated façades are one of the most widely used passive elements that are integrated into buildings, precisely with the aim of reducing these loads. This reduction is due to the airflow induced in the air cavity by the buoyancy forces, when the solar radiation heats the outer layer of the façade. In the open joint ventilated facades (OJVF), ventilation is attained through the open joints between the panels composing the outer layer. Despite the steadily growing research in the characterization of this type of system, few studies combine the numerical modelling of OJVF with experimental results for the assessment of the airflow in the ventilated cavities. This paper experimentally validates a numerical simulation model of an OJVF. Firstly, the façade performance has been experimentally assessed in a laboratory model determining the temperatures in the panels and air gap and measuring the flow field at the gap using particle image velocimetry (PIV) techniques. Secondly, a numerical model has been developed using advanced Computational Fluid Dynamics (CFD) simulation tools. Finally, an experimental validation of the numerical model has been done. Experimental and numerical results are compared in different planes inside the ventilated cavity. The discrete ordinates (DO) radiation model and the k-ε renormalisation group (RNG) turbulence model better adjust the simulated results to the experimental ones.
Keywords
building envelope, CFD simulation, experimental validation, natural convection, PIV, ventilated façades
Suggested Citation
Sánchez MN, Giancola E, Blanco E, Soutullo S, Suárez MJ. Experimental Validation of a Numerical Model of a Ventilated Façade with Horizontal and Vertical Open Joints. (2023). LAPSE:2023.21409
Author Affiliations
Sánchez MN: Department of Energy, Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas, 28040 Madrid, Spain
Giancola E: Department of Energy, Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas, 28040 Madrid, Spain
Blanco E: EDZE (Department of Energy), Universidad de Oviedo, 33271 Gijón (Asturias), Spain
Soutullo S: Department of Energy, Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas, 28040 Madrid, Spain
Suárez MJ: EDZE (Department of Energy), Universidad de Oviedo, 33271 Gijón (Asturias), Spain [ORCID]
Journal Name
Energies
Volume
13
Issue
1
Article Number
E146
Year
2019
Publication Date
2019-12-27
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en13010146, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.21409
This Record
External Link

https://doi.org/10.3390/en13010146
Publisher Version
Download
Files
Mar 22, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
164
Version History
[v1] (Original Submission)
Mar 22, 2023
 
Verified by curator on
Mar 22, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.21409
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version