LAPSE:2023.20878
Published Article

LAPSE:2023.20878
A Novel Photovoltaic Virtual Synchronous Generator Control Technology Without Energy Storage Systems
March 21, 2023
Abstract
Photovoltaic virtual synchronous generator (PV-VSG) technology, by way of simulating the external characteristics of a synchronous generator (SG), gives the PV energy integrated into the power grid through the power electronic equipment the characteristics of inertial response and active frequency response (FR)—this attracts much attention. Due to the high volatility and low adjustability of PV energy output, it does not have the characteristics of a prime mover (PM), so it must be equipped with energy storage systems (ESSs) in the DC or AC side to realize the PV-VSG technology. However, excessive reliance on ESSs will inevitably affect the application of VSG technology in practical PV power plants (PV-PPs). In view of this, this paper proposes the PV power reserve control type VSG (PV-PRC-VSG) control strategy. By reducing the active power output of part of the PV-PPs, the internal PV-PPs can maintain a part of the active power up/down-regulation ability in real time, instead of relying on external ESSs. By adjusting the active reserve power of this part, the output of the PV-PPs can be controlled within a certain range, and the PV-PPs can better simulate the PM characteristics and realize the FR of the grid by combining the VSG technology. At the same time, the factors affecting the reserve ratio are analyzed, and the position of the voltage operating point in PRC mode is deduced. Finally, the simulation results show that the proposed control strategy is effective and correct.
Photovoltaic virtual synchronous generator (PV-VSG) technology, by way of simulating the external characteristics of a synchronous generator (SG), gives the PV energy integrated into the power grid through the power electronic equipment the characteristics of inertial response and active frequency response (FR)—this attracts much attention. Due to the high volatility and low adjustability of PV energy output, it does not have the characteristics of a prime mover (PM), so it must be equipped with energy storage systems (ESSs) in the DC or AC side to realize the PV-VSG technology. However, excessive reliance on ESSs will inevitably affect the application of VSG technology in practical PV power plants (PV-PPs). In view of this, this paper proposes the PV power reserve control type VSG (PV-PRC-VSG) control strategy. By reducing the active power output of part of the PV-PPs, the internal PV-PPs can maintain a part of the active power up/down-regulation ability in real time, instead of relying on external ESSs. By adjusting the active reserve power of this part, the output of the PV-PPs can be controlled within a certain range, and the PV-PPs can better simulate the PM characteristics and realize the FR of the grid by combining the VSG technology. At the same time, the factors affecting the reserve ratio are analyzed, and the position of the voltage operating point in PRC mode is deduced. Finally, the simulation results show that the proposed control strategy is effective and correct.
Record ID
Keywords
active power up-regulation, frequency response (FR), photovoltaic (PV), power reserve control (PRC), virtual synchronous generator (VSG)
Subject
Suggested Citation
Bao G, Tan H, Ding K, Ma M, Wang N. A Novel Photovoltaic Virtual Synchronous Generator Control Technology Without Energy Storage Systems. (2023). LAPSE:2023.20878
Author Affiliations
Bao G: Information Engineering and College of Electrical, Lanzhou University of Technology, Lanzhou 730050, Gansu Province, China
Tan H: State Key Laboratory of Power Transmission Equipment & System Security and Technology, ChongQing University, Chongqing 400044, China
Ding K: Wind Power Technology Center, State Grid Gansu Electric Power Corporation, Lanzhou 730070, Gansu Province, China
Ma M: Wind Power Technology Center, State Grid Gansu Electric Power Corporation, Lanzhou 730070, Gansu Province, China
Wang N: Wind Power Technology Center, State Grid Gansu Electric Power Corporation, Lanzhou 730070, Gansu Province, China
[Login] to see author email addresses.
Tan H: State Key Laboratory of Power Transmission Equipment & System Security and Technology, ChongQing University, Chongqing 400044, China
Ding K: Wind Power Technology Center, State Grid Gansu Electric Power Corporation, Lanzhou 730070, Gansu Province, China
Ma M: Wind Power Technology Center, State Grid Gansu Electric Power Corporation, Lanzhou 730070, Gansu Province, China
Wang N: Wind Power Technology Center, State Grid Gansu Electric Power Corporation, Lanzhou 730070, Gansu Province, China
[Login] to see author email addresses.
Journal Name
Energies
Volume
12
Issue
12
Article Number
E2240
Year
2019
Publication Date
2019-06-12
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en12122240, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.20878
This Record
External Link

https://doi.org/10.3390/en12122240
Publisher Version
Download
Meta
Record Statistics
Record Views
335
Version History
[v1] (Original Submission)
Mar 21, 2023
Verified by curator on
Mar 21, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.20878
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.08 seconds)
[0.08 s]
