LAPSE:2023.20160
Published Article

LAPSE:2023.20160
Load Frequency Control and Automatic Voltage Regulation in Four-Area Interconnected Power Systems Using a Gradient-Based Optimizer
March 17, 2023
Abstract
Existing interconnected power systems (IPSs) are being overloaded by the expansion of the industrial and residential sectors together with the incorporation of renewable energy sources, which cause serious fluctuations in frequency, voltage, and tie-line power. The automatic voltage regulation (AVR) and load frequency control (LFC) loops provide high quality power to all consumers with nominal frequency, voltage, and tie-line power deviation, ensuring the stability and security of IPS in these conditions. In this paper, a proportional integral derivative (PID) controller is investigated for the effective control of a four-area IPS. Each IPS area has five generating units including gas, thermal reheat, hydro, and two renewable energy sources, namely wind and solar photovoltaic plants. The PID controller was tuned by a meta-heuristic optimization algorithm known as a gradient-based optimizer (GBO). The integral of time multiplied by squared value of error (ITSE) was utilized as an error criterion for the evaluation of the fitness function. The voltage, frequency, and tie-line power responses of GBO-PID were evaluated and compared with integral−proportional derivative (GBO-I-PD), tilt integral derivative (GBO-TID), and integral−proportional (GBO-I-P) controllers with 5% step load perturbation (SLP) provided in each of the four areas. Comprehensive comparisons between GBO-PID and other control methodologies revealed that the proposed GBO-PID controller provides superior voltage, frequency, and tie-line power responses in each area. The reliability and efficacy of GBO-PID methodology were further validated with variations in the turbine time constant and speed regulation over a range of  ± 25%. It is evident from the outcomes of the sensitivity analysis that the proposed GBO-PID control methodology is very reliable and can successfully stabilize the deviations in terminal voltage, load frequency, and tie-line power with a shorter settling time in a four-area IPS.
Existing interconnected power systems (IPSs) are being overloaded by the expansion of the industrial and residential sectors together with the incorporation of renewable energy sources, which cause serious fluctuations in frequency, voltage, and tie-line power. The automatic voltage regulation (AVR) and load frequency control (LFC) loops provide high quality power to all consumers with nominal frequency, voltage, and tie-line power deviation, ensuring the stability and security of IPS in these conditions. In this paper, a proportional integral derivative (PID) controller is investigated for the effective control of a four-area IPS. Each IPS area has five generating units including gas, thermal reheat, hydro, and two renewable energy sources, namely wind and solar photovoltaic plants. The PID controller was tuned by a meta-heuristic optimization algorithm known as a gradient-based optimizer (GBO). The integral of time multiplied by squared value of error (ITSE) was utilized as an error criterion for the evaluation of the fitness function. The voltage, frequency, and tie-line power responses of GBO-PID were evaluated and compared with integral−proportional derivative (GBO-I-PD), tilt integral derivative (GBO-TID), and integral−proportional (GBO-I-P) controllers with 5% step load perturbation (SLP) provided in each of the four areas. Comprehensive comparisons between GBO-PID and other control methodologies revealed that the proposed GBO-PID controller provides superior voltage, frequency, and tie-line power responses in each area. The reliability and efficacy of GBO-PID methodology were further validated with variations in the turbine time constant and speed regulation over a range of  ± 25%. It is evident from the outcomes of the sensitivity analysis that the proposed GBO-PID control methodology is very reliable and can successfully stabilize the deviations in terminal voltage, load frequency, and tie-line power with a shorter settling time in a four-area IPS.
Record ID
Keywords
automatic voltage regulation gradient-based optimizer, four-area interconnected power system, load frequency control, meta-heuristic optimization, PID controller, smart grid
Subject
Suggested Citation
Ali T, Malik SA, Daraz A, Adeel M, Aslam S, Herodotou H. Load Frequency Control and Automatic Voltage Regulation in Four-Area Interconnected Power Systems Using a Gradient-Based Optimizer. (2023). LAPSE:2023.20160
Author Affiliations
Ali T: Department of Electrical and Computer Engineering, International Islamic University, Islamabad 44000, Pakistan
Malik SA: Department of Electrical and Computer Engineering, International Islamic University, Islamabad 44000, Pakistan [ORCID]
Daraz A: School of Information Science and Engineering, NingboTech University, Ningbo 315100, China [ORCID]
Adeel M: Department of Electrical and Computer Engineering, International Islamic University, Islamabad 44000, Pakistan [ORCID]
Aslam S: Department of Electrical Engineering and Computer Engineering and Informatics, Cyprus University of Technology, 3036 Limassol, Cyprus
Herodotou H: Department of Electrical Engineering and Computer Engineering and Informatics, Cyprus University of Technology, 3036 Limassol, Cyprus [ORCID]
Malik SA: Department of Electrical and Computer Engineering, International Islamic University, Islamabad 44000, Pakistan [ORCID]
Daraz A: School of Information Science and Engineering, NingboTech University, Ningbo 315100, China [ORCID]
Adeel M: Department of Electrical and Computer Engineering, International Islamic University, Islamabad 44000, Pakistan [ORCID]
Aslam S: Department of Electrical Engineering and Computer Engineering and Informatics, Cyprus University of Technology, 3036 Limassol, Cyprus
Herodotou H: Department of Electrical Engineering and Computer Engineering and Informatics, Cyprus University of Technology, 3036 Limassol, Cyprus [ORCID]
Journal Name
Energies
Volume
16
Issue
5
First Page
2086
Year
2023
Publication Date
2023-02-21
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en16052086, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.20160
This Record
External Link

https://doi.org/10.3390/en16052086
Publisher Version
Download
Meta
Record Statistics
Record Views
328
Version History
[v1] (Original Submission)
Mar 17, 2023
Verified by curator on
Mar 17, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.20160
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.08 seconds)
[0.08 s]
