LAPSE:2023.18837
Published Article
LAPSE:2023.18837
An Optimal Energy Management System for University Campus Using the Hybrid Firefly Lion Algorithm (FLA)
Haneef Ullah, Murad Khan, Irshad Hussain, Ibrar Ullah, Peerapong Uthansakul, Naeem Khan
March 9, 2023
Abstract
As the world population and its dependency on energy is growing exponentially day by day, the existing energy generating resources are not enough to fulfill their needs. In the conventional grid system, most of the generated energy is wasted because of improper demand side management (DSM). This leads to a difficulty in keeping the equilibrium between the user need and electric power production. To overcome these difficulties, smart grid (SG) is introduced, which is composed of the integration of two-way communication between the user and utility. To utilize the existing energy resources in a better way, SG is the best option since a large portion of the generated energy is consumed by the educational institutes. Such institutes also need un-interrupted power supply at the lowest cost. Therefore, in this paper, we have taken a university campus load. We have not only applied two bio-inspired heuristic algorithms for energy scheduling—namely, the Firefly Algorithm (FA) and the Lion Algorithm (LA)—but also proposed a hybrid version, FLA, for more optimal results. Our main objectives are a reduction in both, that is, the cost of energy and the waiting time of consumers or end users. For this purpose, in our proposed model, we have divided all appliances into two categories—shiftable appliances and non-shiftable appliances. Shiftable appliances are feasible to be used in any of the time slots and can be planned according to the day-ahead pricing signal (DAP), provided by the utility, while non-shiftable appliances can be used for a specified duration and cannot be planned with the respective DAP signal. So, we have scheduled shiftable appliances only. We have also used renewable energy sources (RES) for achieving maximum end user benefits. The simulation results show that our proposed hybrid algorithm, FLA, has reduced the cost excellently. We have also taken into consideration the consumers’ waiting times, due to scheduling of appliances.
Keywords
DAP, demand response, DSM, energy management controller (EMC), firefly algorithm (FA), FLA, length of operational time (LOT), lion algorithm (LA), PAR, RES, smart grid, traditional electric power grid
Suggested Citation
Ullah H, Khan M, Hussain I, Ullah I, Uthansakul P, Khan N. An Optimal Energy Management System for University Campus Using the Hybrid Firefly Lion Algorithm (FLA). (2023). LAPSE:2023.18837
Author Affiliations
Ullah H: Faculty of Electrical & Computer Engineering, University of Engineering and Technology, Peshawar 25000, Pakistan
Khan M: Faculty of Electrical & Computer Engineering, University of Engineering and Technology, Peshawar 25000, Pakistan
Hussain I: Faculty of Electrical & Computer Engineering, University of Engineering and Technology, Peshawar 25000, Pakistan [ORCID]
Ullah I: Faculty of Electrical & Computer Engineering, University of Engineering and Technology, Peshawar 25000, Pakistan [ORCID]
Uthansakul P: School of Telecommunication Engineering, Suranaree University of Technology, Nakhon Ratchasima 30000, Thailand [ORCID]
Khan N: Faculty of Electrical & Computer Engineering, University of Engineering and Technology, Peshawar 25000, Pakistan
Journal Name
Energies
Volume
14
Issue
19
First Page
6028
Year
2021
Publication Date
2021-09-22
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14196028, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.18837
This Record
External Link

https://doi.org/10.3390/en14196028
Publisher Version
Download
Files
Mar 9, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
339
Version History
[v1] (Original Submission)
Mar 9, 2023
 
Verified by curator on
Mar 9, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.18837
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version
(0.07 seconds)

[0.07 s]