Abstract
With regard to DC/DC buck converter applications, the objective of this study is to expand the admissible range of the output voltage cut-off frequency while lowering the steady-state current cut-off frequency as possible. This study fortifies the inner loop by incorporating the novel subsystems such as an auto-tuner (for the dynamic current cut-off frequency) and active damping injection invoking the pole-zero cancellation nature with the particular designed feedback gain structure. The outer loop active damping control renders the closed-loop speed transfer function to be a first-order low-pass filter with the cooperation of the specially structured design parameters; in addition, it provides time-varying disturbance attenuation. The experimental results obtained for a 3-kW buck converter validate the feasibility of the proposed technique by showing a 34% performance enhancement (at least) compared with the recent active damping controller.
With regard to DC/DC buck converter applications, the objective of this study is to expand the admissible range of the output voltage cut-off frequency while lowering the steady-state current cut-off frequency as possible. This study fortifies the inner loop by incorporating the novel subsystems such as an auto-tuner (for the dynamic current cut-off frequency) and active damping injection invoking the pole-zero cancellation nature with the particular designed feedback gain structure. The outer loop active damping control renders the closed-loop speed transfer function to be a first-order low-pass filter with the cooperation of the specially structured design parameters; in addition, it provides time-varying disturbance attenuation. The experimental results obtained for a 3-kW buck converter validate the feasibility of the proposed technique by showing a 34% performance enhancement (at least) compared with the recent active damping controller.
Record ID
Keywords
active damping, auto-tuner, DC/DC converter, dynamic current cut-off frequency
Subject
Suggested Citation
Lim S, Kim SK, Kim Y. Active Damping Injection Output Voltage Control with Dynamic Current Cut-Off Frequency for DC/DC Buck Converters. (2023). LAPSE:2023.18804
Author Affiliations
Lim S: Intelligent Robotics Research Center, Korea Electronics Technology Institute, Bucheon 401401, Korea
Kim SK: Department of Creative Convergence Engineering, Hanbat National University, Daejeon 34158, Korea [ORCID]
Kim Y: School of Mechanical Engineering, Chungnam National University, Daejeon 136701, Korea
Kim SK: Department of Creative Convergence Engineering, Hanbat National University, Daejeon 34158, Korea [ORCID]
Kim Y: School of Mechanical Engineering, Chungnam National University, Daejeon 136701, Korea
Journal Name
Energies
Volume
14
Issue
20
First Page
6848
Year
2021
Publication Date
2021-10-19
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14206848, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.18804
This Record
External Link

https://doi.org/10.3390/en14206848
Publisher Version
Download
Meta
Record Statistics
Record Views
210
Version History
[v1] (Original Submission)
Mar 8, 2023
Verified by curator on
Mar 8, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.18804
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.88 seconds) 0.06 + 0.04 + 0.42 + 0.17 + 0 + 0.08 + 0.02 + 0 + 0.02 + 0.06 + 0 + 0