Risk of Using Capillary Active Interior Insulation in a Cold Climate
David Antolinc, Katarina Černe, Zvonko Jagličić
March 7, 2023
Abstract
The retrofitting of cultural heritage buildings for energy efficiency often requires the internal thermal insulation of external walls. Most of the in situ studies of capillary active interior insulation were performed in mild oceanic climate regions, and they showed an excellent performance. However, as a large part of Central−Eastern Europe belongs to a continental climate with cold winters and long periods of temperatures below the freezing temperature, the applicability of the capillary active interior insulation in cold climate was studied. The hydrothermal behaviour of the three walls was determined—each consists of one of three different interior insulations—and the original wall is made of historic regular solid bricks. Two interior thermal insulations were capillary active (aerated cellular concrete, calcium silicate) and one vapour-tight (glass foam). A hot box−cold box experiment and a steady-state model were used to demonstrate an increase in the original wall mass due to the water condensation only when the capillary active interior insulation is used. The combination of the water condensation and the low sub-zero temperature may lead to a risk of freeze−thaw damage to the original wall. The numerical simulation of the water vapour condensation for the considered walls for the Slovenian town Bled with sub-zero average winter temperatures was performed to obtain the whole temperature and moisture profile. It showed good agreement between an experimentally and numerically obtained amount of water condensation. The capillary active interior insulation proved to be unsuitable for improving the thermal insulation of buildings in cold continental climate, and only a vapour-tight system can be recommended.
Keywords
capillary active interior insulation, cold climate, freezing, historic brick wall, water condensation
Suggested Citation
Antolinc D, Černe K, Jagličić Z. Risk of Using Capillary Active Interior Insulation in a Cold Climate. (2023). LAPSE:2023.17879
Author Affiliations
Antolinc D: Faculty of Civil and Geodetic Engineering, University of Ljubljana, Jamova 2, 1000 Ljubljana, Slovenia [ORCID]
Černe K: Faculty of Civil and Geodetic Engineering, University of Ljubljana, Jamova 2, 1000 Ljubljana, Slovenia
Jagličić Z: Faculty of Civil and Geodetic Engineering, University of Ljubljana, Jamova 2, 1000 Ljubljana, Slovenia; Institute of Mathematics, Physics and Mechanics, Jadranska 19, 1000 Ljubljana, Slovenia
Journal Name
Energies
Volume
14
Issue
21
First Page
6890
Year
2021
Publication Date
2021-10-20
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14216890, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.17879
This Record
External Link

https://doi.org/10.3390/en14216890
Publisher Version
Download
Files
Mar 7, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
167
Version History
[v1] (Original Submission)
Mar 7, 2023
 
Verified by curator on
Mar 7, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.17879
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version
(1.84 seconds) 0.19 + 0.24 + 0.84 + 0.31 + 0 + 0.1 + 0.03 + 0 + 0.01 + 0.1 + 0 + 0.01