LAPSE:2023.17725
Published Article
LAPSE:2023.17725
Testing Selected Personal Protection Items of Firefighters in Combined Conditions of Mechanical Loads and Temperatures Occurring during Gas LNG Leaks
March 6, 2023
The article examined selected individual protection used during rescue and fire-extinguishing activities. Fire helmet and special shoes were examined under conditions resembling the operational conditions of LNG gases. The assessment of the equipment consumption was based on strength tests. The main threats come from thermal and mechanical factors. Therefore, firefighters must properly protect their head and legs. At −80 °C, the energy of the impact force of the beater in the headache was, 12.4 J and 15.1 J for points P1 and P2, respectively. The studies showed that cooling the chamber to −80 °C adversely affected the structure of the fire helmet exposed to impact Dynamic. Research work was carried out as part of the Research and Development project No. DOB-BIO9/15/02/2018.
Keywords
fire hazards, firefighting personal protection, Liquified Natural Gas, mechanical loads, thermal loads
Suggested Citation
Ogrodnik P, Powęzka A, Piec R, Zwęgliński T, Smolarkiewicz M, Gromek P, Wróbel R, Węsierski T, Majder-Łopatka M, Wąsik W. Testing Selected Personal Protection Items of Firefighters in Combined Conditions of Mechanical Loads and Temperatures Occurring during Gas LNG Leaks. (2023). LAPSE:2023.17725
Author Affiliations
Ogrodnik P: Institute of Safety Engineering, The Main School of Fire Service, 52/54 Słowackiego Street, 01-629 Warsaw, Poland [ORCID]
Powęzka A: Faculty of Safety Engineering and Civil Protection, The Main School of Fire Service, 52/54 Słowackiego Street, 01-629 Warsaw, Poland [ORCID]
Piec R: Institute of Internal Security, The Main School of Fire Service, 52/54 Słowackiego Street, 01-629 Warsaw, Poland [ORCID]
Zwęgliński T: Institute of Internal Security, The Main School of Fire Service, 52/54 Słowackiego Street, 01-629 Warsaw, Poland [ORCID]
Smolarkiewicz M: Institute of Internal Security, The Main School of Fire Service, 52/54 Słowackiego Street, 01-629 Warsaw, Poland [ORCID]
Gromek P: Institute of Internal Security, The Main School of Fire Service, 52/54 Słowackiego Street, 01-629 Warsaw, Poland [ORCID]
Wróbel R: Faculty of Safety Engineering and Civil Protection, The Main School of Fire Service, 52/54 Słowackiego Street, 01-629 Warsaw, Poland [ORCID]
Węsierski T: Institute of Safety Engineering, The Main School of Fire Service, 52/54 Słowackiego Street, 01-629 Warsaw, Poland
Majder-Łopatka M: Institute of Safety Engineering, The Main School of Fire Service, 52/54 Słowackiego Street, 01-629 Warsaw, Poland [ORCID]
Wąsik W: Faculty of Safety Engineering and Civil Protection, The Main School of Fire Service, 52/54 Słowackiego Street, 01-629 Warsaw, Poland
Journal Name
Energies
Volume
14
Issue
22
First Page
7698
Year
2021
Publication Date
2021-11-17
Published Version
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en14227698, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.17725
This Record
External Link

doi:10.3390/en14227698
Publisher Version
Download
Files
[Download 1v1.pdf] (5.2 MB)
Mar 6, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
118
Version History
[v1] (Original Submission)
Mar 6, 2023
 
Verified by curator on
Mar 6, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.17725
 
Original Submitter
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version