Studies on the Impact of Hydrogen on the Results of THT Measurement Devices
March 3, 2023
Abstract
An essential prerequisite for safe transport and use of natural gas is their appropriate odorization. This enables the detection of uncontrolled gas leaks. Proper and systematic odorization inspection ensures both safe use of gas and continuity of the process itself. In practice, it is conducted through, among others, measuring odorant concentrations in gas. Control devices for rapid gas odorization measurements that are currently used on a large scale in the gas industry are equipped with electrochemical detectors selective for sulfur compounds like tetrahydrothiophene (THT). Because the selectivity of electrochemical detector response to one compound (e.g., THT), the available declarations of manufacturers show that detector sensitivity (indirectly also the quality of the measurement result) is influenced by the presence of increased e.g., sulfur or hydrogen compound content in the gas. Because of the lack of sufficient source literature data in this field, it was necessary to experimentally verify this impact. The results of studies on experimental verification of suspected influence of increased amounts of hydrogen in gas on the response of electrochemical detector was carried out at the Oil and Gas Institute—National Research Institute (INiG—PIB). They are presented in this article. The data gathered in the course of researching the dependence between THT concentration measurement result quality and hydrogen content in gas composition enabled a preliminary assessment of the threat to the safety of end users of gaseous fuels caused by the introduction of this gas into the distribution network. Noticing the scope of necessary changes in the area of odorization is necessary to guarantee this safety.
An essential prerequisite for safe transport and use of natural gas is their appropriate odorization. This enables the detection of uncontrolled gas leaks. Proper and systematic odorization inspection ensures both safe use of gas and continuity of the process itself. In practice, it is conducted through, among others, measuring odorant concentrations in gas. Control devices for rapid gas odorization measurements that are currently used on a large scale in the gas industry are equipped with electrochemical detectors selective for sulfur compounds like tetrahydrothiophene (THT). Because the selectivity of electrochemical detector response to one compound (e.g., THT), the available declarations of manufacturers show that detector sensitivity (indirectly also the quality of the measurement result) is influenced by the presence of increased e.g., sulfur or hydrogen compound content in the gas. Because of the lack of sufficient source literature data in this field, it was necessary to experimentally verify this impact. The results of studies on experimental verification of suspected influence of increased amounts of hydrogen in gas on the response of electrochemical detector was carried out at the Oil and Gas Institute—National Research Institute (INiG—PIB). They are presented in this article. The data gathered in the course of researching the dependence between THT concentration measurement result quality and hydrogen content in gas composition enabled a preliminary assessment of the threat to the safety of end users of gaseous fuels caused by the introduction of this gas into the distribution network. Noticing the scope of necessary changes in the area of odorization is necessary to guarantee this safety.
Record ID
Keywords
gas fuel odorization, gas standards, Hydrogen, mixing hydrogen with natural gas, P2G, safe use of gas, THT
Subject
Suggested Citation
Huszal A, Jaworski J. Studies on the Impact of Hydrogen on the Results of THT Measurement Devices. (2023). LAPSE:2023.16568
Author Affiliations
Journal Name
Energies
Volume
15
Issue
1
First Page
221
Year
2021
Publication Date
2021-12-29
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15010221, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.16568
This Record
External Link

https://doi.org/10.3390/en15010221
Publisher Version
Download
Meta
Record Statistics
Record Views
323
Version History
[v1] (Original Submission)
Mar 3, 2023
Verified by curator on
Mar 3, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.16568
Record Owner
Auto Uploader for LAPSE
Links to Related Works