LAPSE:2023.15146
Published Article

LAPSE:2023.15146
Numerical Modeling of the Hydrodynamic Performance of Slanted Axial-Flow Urban Drainage Pumps at Shut-Off Condition
March 2, 2023
Abstract
Increasing extreme rainfall events caused by global climate change have had a significant impact on urban drainage systems. As a critical component of a pumping station, a large-scale slanted axial-flow pump (SAFP) featuring high specific speed plays a critical role in mitigating urban flooding and waterlogging. In this study, to reveal the transient characteristics of a SAFP at shut-off conditions, a computational fluid dynamics (CFD) based approach with dynamic mesh was proposed. Multiple shut-off conditions with various shut-down speeds of the sluice gate (SG) were modeled. Our analysis demonstrated that both the shut-off conditions and the slanted structure have conspicuous impacts on the hydrodynamic performance of a SAFP. Reducing the shut-down speed leads to a greater reverse flow rate and higher runner speed. The water hammer effect was simulated with different shut-down speeds, increasing the water head by 5.07−10.42 m, the axial force by 163.46−297.06 kN∙m, and the axial moment by 116.05−224.01 kN∙m. Compared with the axial direction, moments in the radial directions were found with more obvious oscillation as a result of stronger rotor−stator interaction. Due to the gravitational effect of the slanted structure, the fluctuation of the runner in vertical direction presented an off-axis characteristic compared with the horizontal one. As the SG speed increased, pressure fluctuations gradually decreased at various locations across the SAFP.
Increasing extreme rainfall events caused by global climate change have had a significant impact on urban drainage systems. As a critical component of a pumping station, a large-scale slanted axial-flow pump (SAFP) featuring high specific speed plays a critical role in mitigating urban flooding and waterlogging. In this study, to reveal the transient characteristics of a SAFP at shut-off conditions, a computational fluid dynamics (CFD) based approach with dynamic mesh was proposed. Multiple shut-off conditions with various shut-down speeds of the sluice gate (SG) were modeled. Our analysis demonstrated that both the shut-off conditions and the slanted structure have conspicuous impacts on the hydrodynamic performance of a SAFP. Reducing the shut-down speed leads to a greater reverse flow rate and higher runner speed. The water hammer effect was simulated with different shut-down speeds, increasing the water head by 5.07−10.42 m, the axial force by 163.46−297.06 kN∙m, and the axial moment by 116.05−224.01 kN∙m. Compared with the axial direction, moments in the radial directions were found with more obvious oscillation as a result of stronger rotor−stator interaction. Due to the gravitational effect of the slanted structure, the fluctuation of the runner in vertical direction presented an off-axis characteristic compared with the horizontal one. As the SG speed increased, pressure fluctuations gradually decreased at various locations across the SAFP.
Record ID
Keywords
dynamic mesh, hydrodynamic performance, shut-off condition, slanted axial-flow pump, sluice gate
Subject
Suggested Citation
Tong Z, Yang Z, Huang Q, Yao Q. Numerical Modeling of the Hydrodynamic Performance of Slanted Axial-Flow Urban Drainage Pumps at Shut-Off Condition. (2023). LAPSE:2023.15146
Author Affiliations
Tong Z: State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310027, China; School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
Yang Z: State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310027, China; School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
Huang Q: Hangzhou Hangfa Electrical Equipment Co., Ltd., Hangzhou 311251, China
Yao Q: Hangzhou Hangfa Electrical Equipment Co., Ltd., Hangzhou 311251, China
Yang Z: State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310027, China; School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
Huang Q: Hangzhou Hangfa Electrical Equipment Co., Ltd., Hangzhou 311251, China
Yao Q: Hangzhou Hangfa Electrical Equipment Co., Ltd., Hangzhou 311251, China
Journal Name
Energies
Volume
15
Issue
5
First Page
1905
Year
2022
Publication Date
2022-03-04
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15051905, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.15146
This Record
External Link

https://doi.org/10.3390/en15051905
Publisher Version
Download
Meta
Record Statistics
Record Views
155
Version History
[v1] (Original Submission)
Mar 2, 2023
Verified by curator on
Mar 2, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.15146
Record Owner
Auto Uploader for LAPSE
Links to Related Works