LAPSE:2023.14954v1
Published Article

LAPSE:2023.14954v1
The Estimation of Lightning Impulses Superimposed onto Pre-Stressed DC Breakdown Voltages Using the Leader Propagation Method
March 2, 2023
Abstract
The impulse breakdown attributes are of rudimentary importance in the insulation coordination in the gas-insulated switchgear (GIS). The critical voltage waveshape for the insulation is the surge over voltages. Usually, such over-voltages will emerge on the electrical equipment while these are burdened under DC or AC working voltages. Therefore, during relatively small-time intervals, the undermined devices are exposed to surge voltages that are superimposed upon the already running DC or AC voltages. From a safety point of view, and for providing reliable power to the consumer, we need to study the breakdown characteristics under such over-voltages, with reference to normal operating voltages (DC or AC). The breakdown mechanism of the GIS under compressed SF6 gas is known to be controlled by a stepped leader propagation method. Although different experimental studies have been conducted by many researchers for different experimental conditions under DC, AC, or impulse high voltages alone, not much research has been performed, in a systematic way, to model and estimate the breakdown voltages of the GIS under such superimposed conditions. This paper presents a systematic model, using a leader propagation technique for the estimation of breakdown voltages for complex voltage conditions, i.e., a lightning impulse (LI) superimposed on pre-stressed DC for different experimental conditions. The estimated values are in good agreement with the measured experimental results.
The impulse breakdown attributes are of rudimentary importance in the insulation coordination in the gas-insulated switchgear (GIS). The critical voltage waveshape for the insulation is the surge over voltages. Usually, such over-voltages will emerge on the electrical equipment while these are burdened under DC or AC working voltages. Therefore, during relatively small-time intervals, the undermined devices are exposed to surge voltages that are superimposed upon the already running DC or AC voltages. From a safety point of view, and for providing reliable power to the consumer, we need to study the breakdown characteristics under such over-voltages, with reference to normal operating voltages (DC or AC). The breakdown mechanism of the GIS under compressed SF6 gas is known to be controlled by a stepped leader propagation method. Although different experimental studies have been conducted by many researchers for different experimental conditions under DC, AC, or impulse high voltages alone, not much research has been performed, in a systematic way, to model and estimate the breakdown voltages of the GIS under such superimposed conditions. This paper presents a systematic model, using a leader propagation technique for the estimation of breakdown voltages for complex voltage conditions, i.e., a lightning impulse (LI) superimposed on pre-stressed DC for different experimental conditions. The estimated values are in good agreement with the measured experimental results.
Record ID
Keywords
breakdown estimation, gas-insulated switchgear (GIS), leader propagation, lightning impulse voltage, superimposed voltage
Subject
Suggested Citation
Meer R, Khan Y, Wani NR, Al-Arainy AA. The Estimation of Lightning Impulses Superimposed onto Pre-Stressed DC Breakdown Voltages Using the Leader Propagation Method. (2023). LAPSE:2023.14954v1
Author Affiliations
Meer R: Department of Electrical Engineering, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia [ORCID]
Khan Y: Department of Electrical Engineering, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia
Wani NR: Department of Electrical Engineering, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia
Al-Arainy AA: Department of Electrical Engineering, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia
Khan Y: Department of Electrical Engineering, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia
Wani NR: Department of Electrical Engineering, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia
Al-Arainy AA: Department of Electrical Engineering, College of Engineering, King Saud University, Riyadh 11421, Saudi Arabia
Journal Name
Energies
Volume
15
Issue
5
First Page
1708
Year
2022
Publication Date
2022-02-24
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15051708, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.14954v1
This Record
External Link

https://doi.org/10.3390/en15051708
Publisher Version
Download
Meta
Record Statistics
Record Views
363
Version History
[v1] (Original Submission)
Mar 2, 2023
Verified by curator on
Mar 2, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.14954v1
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.08 seconds)
[0.08 s]
