Study on Fiber Clogging Mechanism in Sewage Pump Based on CFD−DEM Simulation
March 2, 2023
Abstract
A large number of solid particles and fibrous impurities are always entrained in the fluid transported by a sewage pump, which can easily lead to the blockage of the sewage pump. In view of this, CFD−DEM simulations were conducted in this paper to reveal the fiber clogging mechanism in the sewage pump. A CFD−DEM coupling method with a fiber model was established and verified by an experimental benchmark, i.e., the rectangular flow channel. The method was then applied to a model sewage pump to, after mesh independence tests, analyze the effects of flow rate and fiber length on fiber motion and clogging. The results showed that the position of fiber retention coincides with the position of the vortex, mainly located at the inlet of the impeller, the head of the blade, the middle of the blade, and the tongue in the pump. In the case of a low flow rate, the fiber was more likely to cause blockage in the head of the blade, and in the case of a large flow rate, the fiber would wind around the tongue in the pump. At the same flow rate, long fiber was more likely to stay on the blade’s suction surface.
A large number of solid particles and fibrous impurities are always entrained in the fluid transported by a sewage pump, which can easily lead to the blockage of the sewage pump. In view of this, CFD−DEM simulations were conducted in this paper to reveal the fiber clogging mechanism in the sewage pump. A CFD−DEM coupling method with a fiber model was established and verified by an experimental benchmark, i.e., the rectangular flow channel. The method was then applied to a model sewage pump to, after mesh independence tests, analyze the effects of flow rate and fiber length on fiber motion and clogging. The results showed that the position of fiber retention coincides with the position of the vortex, mainly located at the inlet of the impeller, the head of the blade, the middle of the blade, and the tongue in the pump. In the case of a low flow rate, the fiber was more likely to cause blockage in the head of the blade, and in the case of a large flow rate, the fiber would wind around the tongue in the pump. At the same flow rate, long fiber was more likely to stay on the blade’s suction surface.
Record ID
Keywords
CFD–DEM, fiber blockage, reflux vortex, sewage pump
Subject
Suggested Citation
Zheng S, Yang C, Yan C, Chai M, Sun Z. Study on Fiber Clogging Mechanism in Sewage Pump Based on CFD−DEM Simulation. (2023). LAPSE:2023.14848
Author Affiliations
Zheng S: Institute of Process Equipment and Control Engineering, College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China [ORCID]
Yang C: Institute of Process Equipment and Control Engineering, College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China
Yan C: Institute of Process Equipment and Control Engineering, College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China
Chai M: Institute of Process Equipment and Control Engineering, College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China; State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China [ORCID]
Sun Z: Institute of Process Equipment and Control Engineering, College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China
Yang C: Institute of Process Equipment and Control Engineering, College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China
Yan C: Institute of Process Equipment and Control Engineering, College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China
Chai M: Institute of Process Equipment and Control Engineering, College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China; State Key Laboratory of Clean Energy Utilization, Zhejiang University, Hangzhou 310027, China [ORCID]
Sun Z: Institute of Process Equipment and Control Engineering, College of Mechanical Engineering, Zhejiang University of Technology, Hangzhou 310023, China
Journal Name
Energies
Volume
15
Issue
5
First Page
1598
Year
2022
Publication Date
2022-02-22
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15051598, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.14848
This Record
External Link

https://doi.org/10.3390/en15051598
Publisher Version
Download
Meta
Record Statistics
Record Views
331
Version History
[v1] (Original Submission)
Mar 2, 2023
Verified by curator on
Mar 2, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.14848
Record Owner
Auto Uploader for LAPSE
Links to Related Works
(0.11 seconds)
[0.12 s]