LAPSE:2023.14215
Published Article
LAPSE:2023.14215
Measurement of the Green Façade Prototype in a Climate Chamber: Impact of Watering Regime on the Surface Temperatures
Peter Juras, Pavol Durica
March 1, 2023
Abstract
Green façades with an active water regime and the water flowing through the substrate itself are not common. This system reduces the temperatures and incorporates the evapotranspiration, which could be more effective than by the regular green façades. The use of a double-skin façade with a ventilated air cavity can reduce the heat load, but the evapotranspiration can reduce it even more with additional benefits. Green façades could also serve as a key element for reducing the surface temperatures of the insulated metal panels (IMP), which are mostly used as a façade system for production facilities or factories. In this paper, a prototype of a double-skin façade, which consisted of vegetation board from recycled materials and IMP, is tested in a climate chamber to evaluate the function and benefits of such a combination. The outdoor skin is made from board, the surface of which is covered by the rooted succulent plants. Measurement results are represented as a direct comparison of single sunny day surface temperatures with and without a double-skin (green) façade. The use of the green façade reduces the indoor surface temperature of IMP by 2.8 °C in this measurement. The use of water circulation through the outdoor skin reduces the temperature of the vegetation board by 28 °C. This could have a great impact on the microclimate around the façade. Because of the controlled environment and ventilation system in a climate chamber, it is not possible to investigate the airflow and solar chimney effect within the ventilated cavity. In addition, it is complicated to show the potential of microclimate change caused by the wet vegetation surface. For the mentioned reasons, the need to carry out “in situ” tests on a model wall under the real conditions was indicated.
Keywords
air cavity, evapotranspiration, experimental, irrigation, overheating, recycling, vegetation
Subject
Suggested Citation
Juras P, Durica P. Measurement of the Green Façade Prototype in a Climate Chamber: Impact of Watering Regime on the Surface Temperatures. (2023). LAPSE:2023.14215
Author Affiliations
Juras P: Department of Building Engineering and Urban Planning, Faculty of Civil Engineering, University of Zilina, Univerzitna 8215/1, 010 26 Zilina, Slovakia [ORCID]
Durica P: Department of Building Engineering and Urban Planning, Faculty of Civil Engineering, University of Zilina, Univerzitna 8215/1, 010 26 Zilina, Slovakia
Journal Name
Energies
Volume
15
Issue
7
First Page
2459
Year
2022
Publication Date
2022-03-27
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15072459, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.14215
This Record
External Link

https://doi.org/10.3390/en15072459
Publisher Version
Download
Files
Mar 1, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
155
Version History
[v1] (Original Submission)
Mar 1, 2023
 
Verified by curator on
Mar 1, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.14215
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version