Abstract
Due to their simple design and reliable operation, earth-to-air heat exchangers (EAHE) are used in modern buildings to reduce ventilation heat losses. EAHE operation in atmospheric conditions results in variation in ambient air temperature and pressure affecting air density. The paper presents the study on the impact of ambient air density variation on the calculated hourly air temperature at the EAHE outlet and the resulting energy use for space heating and cooling of an exemplary residential building. The ground temperature was computed from the model given in EN 16798-5-1. Then, air density was obtained using five various methods. Energy use for space heating and cooling of the building was computed using the 5R1C thermal network model of EN ISO 13790. Depending on the chosen method and concerning the base case without EAHE, a reduction in annual heating and cooling needs was obtained from 7.5% to 8.8% in heating and from 15.3% to 19% in cooling. Annual heating and cooling gain from EAHE were 600.9 kWh and 628.3 kWh for heating and 616.9 kWh and 603.5 kWh for cooling for the Typical Meteorological Years (TMY) and International Weather for Energy Calculation (IWEC) files, respectively. Unit heating and cooling gains per heat exchanger area were from 34.9 kWh/m2 to 36.8 kWh/m2 and from −35.1 kWh/m2 to −36.3 kWh/m2. Density variation with temperature from the relevant typical Polish meteorological year at constant pressure, in comparison to the method of EN 16798-5-1, resulted in an hourly difference of that unit gain up to 4.3 W/m2 and 2.0 W/m2 for heating and cooling, respectively. The same was true inthe case of IWEC files that resulted in differences of 5.5 W/m2 and 1.1 W/m2.
Keywords
5R1C model, air density, barometric formula, EAHE, earth-to-air heat exchanger, EN ISO 13790, ground temperature, hourly simulation, outlet temperature, specific heat of air
Suggested Citation
Michalak P. Impact of Air Density Variation on a Simulated Earth-to-Air Heat Exchanger’s Performance. (2023). LAPSE:2023.13573
Author Affiliations
Michalak P: Department of Power Systems and Environmental Protection Facilities, Faculty of Mechanical Engineering and Robotics, AGH University of Science and Technology, Mickiewicza 30, 30-059 Krakow, Poland [ORCID]
Journal Name
Energies
Volume
15
Issue
9
First Page
3215
Year
2022
Publication Date
2022-04-27
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15093215, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.13573
This Record
External Link

https://doi.org/10.3390/en15093215
Publisher Version
Download
Files
Mar 1, 2023
Main Article
License
CC BY 4.0
Meta
Record Statistics
Record Views
196
Version History
[v1] (Original Submission)
Mar 1, 2023
 
Verified by curator on
Mar 1, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.13573
 
Record Owner
Auto Uploader for LAPSE
Links to Related Works
Directly Related to This Work
Publisher Version
(0.24 seconds)