Experimental Investigation of Heat Transfer and Flow Characteristics of Split Natural Cooling System for Data Center Based on Micro Heat Pipe Array
February 28, 2023
Abstract
This paper presents a new type of split natural cooling system that maximizes the use of natural cold energy to significantly reduce the power consumption of the air conditioning system in data centers. A split natural cooling system module, which consisted of indoor and outdoor heat exchanger based on micro heat pipe arrays connected by liquid circulation system, was selected for experimental research. The heat transfer process and flow characteristics were analyzed under different outdoor environment temperatures, air and water flow rates, and different ratios of heat transfer components (N) of indoor and outdoor heat exchangers. To improve the utilization of natural cold energy, two kinds of heat dissipation conditions, namely room and heat channel-based, were proposed. The indoor temperature of two conditions at 28 °C and 38 °C were simulated in the laboratory at constant temperature-humidity, respectively. Results indicated that the air flow rate had a greater influence on the heat transfer performance than the water flow rate. The pressure drop of the air and water sides was at a lower level, and the fitting curve of the pressure drop was obtained to provide a reference for the heat exchanger design and equipment selection. When the ratio of heat transfer components (N) of the indoor and outdoor heat exchanger was approximately 0.75, the split natural cooling system showed optimal comprehensive performance. Under heat channel-based conditions, the maximum heat transfer rate reached 12.4 kW, and the maximum energy efficiency ratio was 17.15; the maximum heat transfer rate and the maximum energy efficiency ratio increased by 42.5% and 22.64% compared with the room-based condition, respectively. The fitting curve of the energy efficiency ratio was calculated under different outdoor temperatures at two heat dissipation conditions.
This paper presents a new type of split natural cooling system that maximizes the use of natural cold energy to significantly reduce the power consumption of the air conditioning system in data centers. A split natural cooling system module, which consisted of indoor and outdoor heat exchanger based on micro heat pipe arrays connected by liquid circulation system, was selected for experimental research. The heat transfer process and flow characteristics were analyzed under different outdoor environment temperatures, air and water flow rates, and different ratios of heat transfer components (N) of indoor and outdoor heat exchangers. To improve the utilization of natural cold energy, two kinds of heat dissipation conditions, namely room and heat channel-based, were proposed. The indoor temperature of two conditions at 28 °C and 38 °C were simulated in the laboratory at constant temperature-humidity, respectively. Results indicated that the air flow rate had a greater influence on the heat transfer performance than the water flow rate. The pressure drop of the air and water sides was at a lower level, and the fitting curve of the pressure drop was obtained to provide a reference for the heat exchanger design and equipment selection. When the ratio of heat transfer components (N) of the indoor and outdoor heat exchanger was approximately 0.75, the split natural cooling system showed optimal comprehensive performance. Under heat channel-based conditions, the maximum heat transfer rate reached 12.4 kW, and the maximum energy efficiency ratio was 17.15; the maximum heat transfer rate and the maximum energy efficiency ratio increased by 42.5% and 22.64% compared with the room-based condition, respectively. The fitting curve of the energy efficiency ratio was calculated under different outdoor temperatures at two heat dissipation conditions.
Record ID
Keywords
data center, energy efficiency ratio, heat transfer, micro heat pipe array, pressure drop, split natural cooling system
Subject
Suggested Citation
Jing H, Quan Z, Zhao Y, Wang L, Ren R, Dong R, Wu Y. Experimental Investigation of Heat Transfer and Flow Characteristics of Split Natural Cooling System for Data Center Based on Micro Heat Pipe Array. (2023). LAPSE:2023.12406v1
Author Affiliations
Jing H: Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China; MOE Key Laboratory of Enhanced Heat Transfer and Energy Conservation, Beijing Key Laboratory of Heat Transfer and E
Quan Z: Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China [ORCID]
Zhao Y: Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China
Wang L: Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China
Ren R: Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China
Dong R: Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China
Wu Y: MOE Key Laboratory of Enhanced Heat Transfer and Energy Conservation, Beijing Key Laboratory of Heat Transfer and Energy Conversion, Beijing University of Technology, Beijing 100124, China
Quan Z: Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China [ORCID]
Zhao Y: Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China
Wang L: Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China
Ren R: Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China
Dong R: Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing 100124, China
Wu Y: MOE Key Laboratory of Enhanced Heat Transfer and Energy Conservation, Beijing Key Laboratory of Heat Transfer and Energy Conversion, Beijing University of Technology, Beijing 100124, China
Journal Name
Energies
Volume
15
Issue
12
First Page
4250
Year
2022
Publication Date
2022-06-09
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15124250, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.12406v1
This Record
External Link

https://doi.org/10.3390/en15124250
Publisher Version
Download
Meta
Record Statistics
Record Views
197
Version History
[v1] (Original Submission)
Feb 28, 2023
Verified by curator on
Feb 28, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.12406v1
Record Owner
Auto Uploader for LAPSE
Links to Related Works