LAPSE:2023.12154
Published Article

LAPSE:2023.12154
Steam Temperature Characteristics in Boiler Water Wall Tubes Based on Furnace CFD and Hydrodynamic Coupling Model
February 28, 2023
Abstract
With the development of power plant units of higher capacity and with improved parameters, the proportion of high-capacity units for generating power has increased; this requires large capacity units to take responsibility for power-grid peak shaving. When the boiler operates at low loads, the working fluid in the boiler water wall tubes is subjected to high heat flux in the furnace, which can cause heat transfer deterioration, tube overheating or even leakage. Therefore, it is particularly important to study the reliability of the boiler hydrodynamic cycle during peak shaving (low load operation). This study takes a 1000 MW ultra-supercritical single-reheat Π type boiler with single furnace and double tangential firing as the research object. A furnace Computational Fluid Dynamics (CFD) and hydrodynamic coupling analysis model is established and verified according to the actual operating conditions on site. The calculation results show that the simulated value is in good agreement with the actual operating value. Therefore, the model established in this study can reflect the real situation of the on-site furnace to a certain extent, and has high reliability. Based on the fitting results, the causes of steam temperature deviation of the boiler water wall are analyzed, and measures to reduce the deviation are proposed to provide a necessary basis for power plant operation and boiler design.
With the development of power plant units of higher capacity and with improved parameters, the proportion of high-capacity units for generating power has increased; this requires large capacity units to take responsibility for power-grid peak shaving. When the boiler operates at low loads, the working fluid in the boiler water wall tubes is subjected to high heat flux in the furnace, which can cause heat transfer deterioration, tube overheating or even leakage. Therefore, it is particularly important to study the reliability of the boiler hydrodynamic cycle during peak shaving (low load operation). This study takes a 1000 MW ultra-supercritical single-reheat Π type boiler with single furnace and double tangential firing as the research object. A furnace Computational Fluid Dynamics (CFD) and hydrodynamic coupling analysis model is established and verified according to the actual operating conditions on site. The calculation results show that the simulated value is in good agreement with the actual operating value. Therefore, the model established in this study can reflect the real situation of the on-site furnace to a certain extent, and has high reliability. Based on the fitting results, the causes of steam temperature deviation of the boiler water wall are analyzed, and measures to reduce the deviation are proposed to provide a necessary basis for power plant operation and boiler design.
Record ID
Keywords
1000 MW, boiler, coupling model, hydrodynamic, low load, User Defined Function (UDF)
Subject
Suggested Citation
Guo X, Xia L, Zhao G, Wei G, Wang Y, Yin Y, Guo J, Ren X. Steam Temperature Characteristics in Boiler Water Wall Tubes Based on Furnace CFD and Hydrodynamic Coupling Model. (2023). LAPSE:2023.12154
Author Affiliations
Guo X: Research Institute of Boiler, Harbin Boiler Company Limited, Harbin 150001, China; School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China
Xia L: Research Institute of Boiler, Harbin Boiler Company Limited, Harbin 150001, China
Zhao G: School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China
Wei G: Research Institute of Boiler, Harbin Boiler Company Limited, Harbin 150001, China; School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China
Wang Y: Research Institute of Boiler, Harbin Boiler Company Limited, Harbin 150001, China
Yin Y: Research Institute of Boiler, Harbin Boiler Company Limited, Harbin 150001, China
Guo J: Research Institute of Boiler, Harbin Boiler Company Limited, Harbin 150001, China
Ren X: Institute of Thermal Science and Technology, Shandong University, Jinan 250061, China [ORCID]
Xia L: Research Institute of Boiler, Harbin Boiler Company Limited, Harbin 150001, China
Zhao G: School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China
Wei G: Research Institute of Boiler, Harbin Boiler Company Limited, Harbin 150001, China; School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China
Wang Y: Research Institute of Boiler, Harbin Boiler Company Limited, Harbin 150001, China
Yin Y: Research Institute of Boiler, Harbin Boiler Company Limited, Harbin 150001, China
Guo J: Research Institute of Boiler, Harbin Boiler Company Limited, Harbin 150001, China
Ren X: Institute of Thermal Science and Technology, Shandong University, Jinan 250061, China [ORCID]
Journal Name
Energies
Volume
15
Issue
13
First Page
4745
Year
2022
Publication Date
2022-06-28
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15134745, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.12154
This Record
External Link

https://doi.org/10.3390/en15134745
Publisher Version
Download
Meta
Record Statistics
Record Views
182
Version History
[v1] (Original Submission)
Feb 28, 2023
Verified by curator on
Feb 28, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.12154
Record Owner
Auto Uploader for LAPSE
Links to Related Works
