Abstract
Underground or submarine cables have a higher capacitance component than overhead lines, and they inject a large amount of capacitive reactive power into the system. A separate reactive power compensation device is required in order for a wind power plant (WPP) connected to the public network with a cable to meet the reactive power requirements required by the grid code. In this paper, a reactive power control using a variable shunt reactor (VSR) was proposed to satisfy the reactive power requirement required by the grid code for a WPP connected to the grid through a cable. The proposed reactive power control method compensates for the capacitive reactive power of the cable by using a VSR, and it follows the reactive power command through the reactive power control of a WPP. In the section where it is difficult to follow the WPP reactive power command only with the reactive power capacity of a WPP due to cable losses or a cable reactive power compensation error of the VSR, the reactive power control is additionally supported through the hysteresis control of the VSR. The proposed method satisfies the grid codes, and it enables fast and accurate reactive power control. The performance of the proposed method was verified through simulation using MATLAB/Simulink.
Underground or submarine cables have a higher capacitance component than overhead lines, and they inject a large amount of capacitive reactive power into the system. A separate reactive power compensation device is required in order for a wind power plant (WPP) connected to the public network with a cable to meet the reactive power requirements required by the grid code. In this paper, a reactive power control using a variable shunt reactor (VSR) was proposed to satisfy the reactive power requirement required by the grid code for a WPP connected to the grid through a cable. The proposed reactive power control method compensates for the capacitive reactive power of the cable by using a VSR, and it follows the reactive power command through the reactive power control of a WPP. In the section where it is difficult to follow the WPP reactive power command only with the reactive power capacity of a WPP due to cable losses or a cable reactive power compensation error of the VSR, the reactive power control is additionally supported through the hysteresis control of the VSR. The proposed method satisfies the grid codes, and it enables fast and accurate reactive power control. The performance of the proposed method was verified through simulation using MATLAB/Simulink.
Record ID
Keywords
coordinated control, reactive power control, Renewable and Sustainable Energy, variable shunt reactor, voltage regulation
Subject
Suggested Citation
Song SH, Kim SB. Coordinated Reactive Power Control with a Variable Shunt Reactor and an Inverter-Based Wind Power Plant. (2023). LAPSE:2023.12149
Author Affiliations
Song SH: Department of Electrical Engineering, Kwangwoon University, Seoul 01897, Korea [ORCID]
Kim SB: Korea Electric Power Research Institute, Daejeon 34056, Korea
Kim SB: Korea Electric Power Research Institute, Daejeon 34056, Korea
Journal Name
Energies
Volume
15
Issue
13
First Page
4739
Year
2022
Publication Date
2022-06-28
ISSN
1996-1073
Version Comments
Original Submission
Other Meta
PII: en15134739, Publication Type: Journal Article
Record Map
Published Article

LAPSE:2023.12149
This Record
External Link

https://doi.org/10.3390/en15134739
Publisher Version
Download
Meta
Record Statistics
Record Views
194
Version History
[v1] (Original Submission)
Feb 28, 2023
Verified by curator on
Feb 28, 2023
This Version Number
v1
Citations
Most Recent
This Version
URL Here
https://psecommunity.org/LAPSE:2023.12149
Record Owner
Auto Uploader for LAPSE
Links to Related Works